Sensors-Controllers-Accessories
-
Dynair RVM Single-phase self-transformer speed regulator 1,5 A
Construction
- Supply 230V-1Ph-50/60Hz.
- Nominal current max 1,5 A.
- Output voltage 1(60V)-2(100V)-3(135V)- 4(160V)-5(185V)-6(230V).
- Protection IP 55.
- Pilot light
- Housing in die-cast aluminium RAL 7001 (grey).
- Weight Kg 2,5.
Accessories
- Supply 230V-1Ph-50/60Hz.
- Nominal current max 1,5 A.
- Output voltage 1(60V)-2(100V)-3(135V)- 4(160V)-5(185V)-6(230V).
- Protection IP 55.
- Pilot light
- Housing in die-cast aluminium RAL 7001 (grey).
- Weight Kg 2,5.
CATALOGUE
-
Dynair R10 Single-phase electronic speed regulator 1 A
Construction
- Infinitely variable electronic speed controller by potentiometer
- New design with cover
- ON/OFF light switch
- Suitable for surface and built-in application
- Ease of connection by the means of removable terminals
- External trimmer for the adjustment of the fan minimum speed
- Protection fuse
- Single-phase 230V – 50/60 Hz
- Max. load 1 A
- Protection IP42
- Weight 0,5 Kg
- Dimensions 110x80x42
- CE marked
CATALOGUE
-
Dynair R15 Single-phase electronic speed regulator 1.5 A
Construction
- Infinitely variable electronic speed controller by potentiometer
- New design with cover
- ON/OFF light switch
- Suitable for surface and built-in application
- Ease of connection by the means of removable terminals
- External trimmer for the adjustment of the fan minimum speed
- Protection fuse
- Single-phase 230V – 50/60 Hz
- Max. load 1.5 A
- Protection IP42
- Weight 0,5 Kg
- Dimensions 110x80x42
- CE marked
CATALOGUE
-
Dynair RV/2 Single-phase electronic speed regulator 7 A
Construction
- Supply 230V-1Ph-50/60Hz.
- Nominal current max 7 A (min. 4 A).
- Timed protection fuse 8A/250V.
- Minimum speed setting tuner.
- Radio noise filter EMC.
- Pilot light.
- Housing in techno-polymer RAL 9016 (white).
- Cooling fi n in extruded aluminium.
- Protection IP 42.
- Weight Kg 0,7.
-
Dynair RVS Single-phase self-transformer speed regulator 0,5 A
Construction
- Supply 230V-1Ph-50/60Hz.
- Nominal current max 0,5 A.
- Output voltage 1(125V)-2(140V)-3(160V)-4(200V)-5(230V).
- Protection IP 42.
- Housing in techno-polymer RAL9016 (white).
- Weight Kg 0,7.
CATALOGUE
-
Dynair RVM/2 Single-phase self-transformer speed regulator 4 A
CONSTRUCTION
- Supply 220/240V-1Ph-50/60Hz.
- Nominal current max 4 A.
- Output voltage 1(60V)-2(105V)-3(130V)-4(160V)-5(230V)
- Protection IP 55.
- Pilot light
- Housing in die-cast aluminium RAL 7001 (grey).
- Weight Kg 5.
CATALOGUE
-
Dynair RVM/3 Single-phase self-transformer speed regulator 7 A
CONSTRUCTION
- Supply 220/240V-1Ph-50/60Hz.
- Nominal current max 7 A.
- Output voltage 1(60V)-2(105V)-3(130V)-4(160V)-5(230V)
- Protection IP 55.
- Pilot light
- Housing in die-cast aluminium RAL 7001 (grey).
- Weight Kg 8.3
CATALOGUE
-
Dynair RVT Threephase self-transformer speed regulator 2A
CONSTRUCTION
- Supply 400V-3Ph-50/60Hz.
- Nominal current max 2 A.
- Output voltage 1(90V)-2(140V)-3(180V)-4(230V)-5(400V).
- Protection IP 54.
- Pilot light
- Housing in die-cast aluminium RAL 7001 (grey) with cover in plastic material RAL7035 (light)
- Weight Kg 7.5
CATALOGUE
-
Dynair RVT1 Threephase self-transformer speed regulator 4A
CONSTRUCTION
- Supply 400V-3Ph-50/60Hz.
- Nominal current max 4 A.
- Output voltage 1(95V)-2(145V)-3(190V)-4(240V)-5(400V).
- Protection IP 55.
- Pilot light
- Housing in die-cast aluminium RAL 7001 (grey)
- Weight Kg 11.
CATALOGUE
-
Dynair RVT/2 Threephase self-transformer speed regulator 7A
CONSTRUCTION
- Supply 400V-3Ph-50/60Hz.
- Nominal current max 7 A.
- Output voltage 1(90V)-2(140V)-3(180V)-4(230V)-5(400V).
- Protection IP 21.
- Pilot light
- Housing in die-cast aluminium RAL 7001 (grey) with cover in coated steel sheet RAL 7035 (light grey).
- Weight Kg 20.
CATALOGUE
-
Dynair Inverter and Line filter
VSD – Variable Speed Drive.
- SPWM Control
- Integrated EMI filter
- Settable operation functions
- Interface MODBAS RS485.
- Upon request DeviceNet, Profi bus, Lon Works, CANopen protocols
- Wall installation, optional DIN bar
VFD “EL”: Keypad with incorporated fixed potentiometer.
VFD “E”: Integrated PLC. Keypad with removable potentiometer, ideal for multiple installations with a unique and remote-manageable programmation (a cable of 5 mt max. length is available upon request). Mounting port for extension card available.CATALOGUE