<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>High temperature fans (200°C) &#8211; Dynair.hu</title>
	<atom:link href="https://www.dynair.hu/term%C3%A9kkateg%C3%B3ria/high-temperature-fans-200c/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.dynair.hu</link>
	<description>Dynair ventilation</description>
	<lastBuildDate>Tue, 23 Aug 2022 09:10:26 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.dynair.hu/wp-content/uploads/2022/01/favicon.jpg</url>
	<title>High temperature fans (200°C) &#8211; Dynair.hu</title>
	<link>https://www.dynair.hu</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Dynair PQ-L Backward curved blade centrifugal fans for dusty air</title>
		<link>https://www.dynair.hu/termek/dynair-pq-l-backward-curved-blade-centrifugal-fans-for-dusty-air/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:13 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8120/</guid>

					<description><![CDATA[<p>The PQ-L series of fans are designed  for industrial or commercial applications, for heating, ventilation, air-conditioning, or filtering in large estabilishments. They can also be used in many different manufacturing processes(lumber industry, chemical industry, mills, mines, foundries, etc.). PQ-L fans can convey somke, or slightly dusty air without abrasive particles, with temperatures between -20°C and +80°C  in standard configurations, and up to 300°C in special versions. This series features both belt-driven(execution 4) and direct drive(execution 1,9,12) versions, suitable for applications with high airflow  and moderately high pressure.</p>
<p>Airflow: up to 120 000m<sup>3</sup>/h<br />
Max static pressure buildup: 14 500 Pa<br />
Max operating temperature: 80°C</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<p><a href="https://www.dynair.hu/termek/dynair-pq-l-inox-backward-curved-blade-centrifugal-fans-for-dusty-air/" target="_blank" rel="noopener">PQ-L/INOX</a> stainless steel version<br />
<a href="https://www.dynair.hu/termek/dynair-pq-l-atex-backward-curved-blade-centrifugal-fans/" target="_blank" rel="noopener">PQ-L ATX</a> ATEX anti-explosion version</p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/PQ-L-catalogue.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-pq-l-backward-curved-blade-centrifugal-fans-for-dusty-air/">Dynair PQ-L Backward curved blade centrifugal fans for dusty air</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Volute casing made out of steel sheet, protected against atmospheric agenty by epoxy paint.</li>
<li>Aerodynamically shaped inlet cone, made from steel sheet, covered in epoxy paint.</li>
<li>Single inlet, high efficiency  backward-curved steel impeller. Class 3 versions are suited for operation at high speed.</li>
<li>For executions 1,9,12, a cast iron mono-block support is used, with ball bearings, designed for easy lubrication. Pulleys, belts, motor support and belt protection guard supplied as standard.</li>
<li>Asynchronous three-phase motor, with IP55 protection, Class F insulation, CE marked, compliant with the following standards: IEC 60034, IEC 60072, EMC 2004=108/CE, LVD 2006/95/CE. Suitable for S1 service (continuous operation at constant load).</li>
</ul>
<p><strong>Accessoreies:</strong></p>
<ul>
<li>Condensation drain hole (TS)</li>
<li>Inspection door (PI)</li>
<li>Inlet counter flange(CFA)</li>
<li>Outlet counter flange(CFP)</li>
<li>Inlet protection guard(RA)</li>
<li>Outlet protection guard(RP)</li>
<li>Inlet flexible connector(GA)</li>
<li>Outlet flexible connector(GP)</li>
<li>Inlet vane control</li>
<li>Outlet setting shutter</li>
<li>Anti-vibration mounts</li>
</ul>
<p><strong>Special versions:</strong></p>
<ul>
<li><a href="https://www.dynair.hu/termek/dynair-pq-l-inox-backward-curved-blade-centrifugal-fans-for-dusty-air/" target="_blank" rel="noopener">Corrosion resistant version</a>, featuring an AISI 304 stainles steel casing, inlet and impeller
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See:<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/anticorrosion-fans/" target="_blank" rel="noopener">Anticorrosion fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-pq-l-atex-backward-curved-blade-centrifugal-fans/" target="_blank" rel="noopener">ATEX version</a>, compliant with Directives 94/9/CE  and 2014/34/EU.
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See:<a href="https://www.dynair.hu/term%C3%A9kkateg%C3%B3ria/atex-fans/" target="_blank" rel="noopener">ATEX Fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-pq-l-backward-curved-blade-centrifugal-fans-for-dusty-air/">Dynair PQ-L Backward curved blade centrifugal fans for dusty air</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair PR-L Backward curved blade centrifugal fans for clean or slightly dusty air</title>
		<link>https://www.dynair.hu/termek/dynair-pr-l-backward-curved-blade-centrifugal-fans-for-clean-or-slightly-dusty-air/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:13 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8123/</guid>

					<description><![CDATA[<p>The PR-L series of fans are designed  for industrial or commercial applications, for heating, ventilation, air-conditioning, or filtering in large estabilishments. They can be used in other industrial processes as well, such as baker ovens, spray booths, boilers, silos, cooling systems, etc. PR-L fans can convey clean air, smoke or even slightly dusty air with temperatures between -20°C and +80°C  in standard configurations, and up to 300°C in special versions. This series features both belt-driven(execution 4) and direct drive(execution 1,9,12) versions, suitable for applications with high airflow  at a low pressure.</p>
<p>Airflow: up to 105 000 m<sup>3</sup>/h<br />
Max static pressure buildup: 5 000 Pa<br />
Max operating temperature: 80°C</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<p><a href="https://www.dynair.hu/hu/termek/dynair-pr-l-nagyteljesitmenyu-radialventilator-hatrahajlo-lapatozassal/" target="_blank" rel="noopener">PR-L/AT</a> high temp version<br />
<a href="https://www.dynair.hu/hu/termek/dynair-pr-l-inox-nagyteljesitmenyu-radialventilator-hatrahajlo-lapatozassal/" target="_blank" rel="noopener">PR-L/INOX</a> stainless steel version<br />
<a href="https://www.dynair.hu/hu/termek/dynair-pr-l-atx-robbanasbiztos-hatrahajlo-lapatozasu-nagyteljesitmenyu-radialventilator/" target="_blank" rel="noopener">PR-L ATX</a> ATEX version</p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/PR-L-catalogue.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-pr-l-backward-curved-blade-centrifugal-fans-for-clean-or-slightly-dusty-air/">Dynair PR-L Backward curved blade centrifugal fans for clean or slightly dusty air</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Volute casing made out of steel sheet, protected against atmospheric agenty by epoxy paint.</li>
<li>Aerodynamically shaped inlet cone, made from steel sheet, covered in epoxy paint.</li>
<li>Single inlet, high efficiency  backward-curved steel impeller. Class 3 versions are suited for operation at high speed.</li>
<li>For executions 1,9,12, a cast iron mono-block support is used, with ball bearings, designed for easy lubrication. Pulleys, belts, motor support and belt protection guard supplied as standard.</li>
<li>Asynchronous three-phase motor, with IP55 protection, Class F insulation, CE marked, compliant with the following standards: IEC 60034, IEC 60072, EMC 2004=108/CE, LVD 2006/95/CE. Suitable for S1 service (continuous operation at constant load).</li>
</ul>
<p><strong>Accessoreies:</strong></p>
<ul>
<li>Condensation drain hole (TS)</li>
<li>Inspection door (PI)</li>
<li>Inlet counter flange(CFA)</li>
<li>Outlet counter flange(CFP)</li>
<li>Inlet protection guard(RA)</li>
<li>Outlet protection guard(RP)</li>
<li>Inlet flexible connector(GA)</li>
<li>Outlet flexible connector(GP)</li>
<li>Inlet vane control</li>
<li>Outlet setting shutter</li>
<li>Anti-vibration mounts</li>
</ul>
<p><strong>Special versions:</strong></p>
<ul>
<li><a href="https://www.dynair.hu/termek/pr-l-at-inox-backward-curved-blade-centrifugal-fans-for-clean-or-slightly-dusty-air/" target="_blank" rel="noopener">High temperature version</a>, suitable for conveying hot gases (up to 150°C or 300°C)
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See:<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/high-temperature-fans-200c/" target="_blank" rel="noopener">High temperature fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-pr-l-inox-backward-curved-blade-centrifugal-fans-for-clean-or-slightly-dusty-air/" target="_blank" rel="noopener">Corrosion resistant version</a>, featuring an AISI 304 stainles steel casing, inlet and impeller
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See:<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/anticorrosion-fans/" target="_blank" rel="noopener">Anticorrosion fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-pr-l-atex-backward-curved-blade-centrifugal-fans-for-clean-or-slightly-dusty-air/" target="_blank" rel="noopener">ATEX version</a>, compliant with Directives 94/9/CE  and 2014/34/EU.
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See:<a href="https://www.dynair.hu/term%C3%A9kkateg%C3%B3ria/atex-fans/" target="_blank" rel="noopener">ATEX Fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-pr-l-backward-curved-blade-centrifugal-fans-for-clean-or-slightly-dusty-air/">Dynair PR-L Backward curved blade centrifugal fans for clean or slightly dusty air</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair PS-L Backward curved blade centrifugal fans for dusty air</title>
		<link>https://www.dynair.hu/termek/dynair-ps-l-backward-curved-blade-centrifugal-fans-for-dusty-air/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:13 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8122/</guid>

					<description><![CDATA[<p>The PS-L series of fans are designed  for industrial or commercial applications, for heating, ventilation, air-conditioning, or filtering in large estabilishments. They can also be used in many different manufacturing processes(lumber industry, chemical industry, mills, mines, foundries, etc.). PS-L fans can convey somke, or very dusty air without abrasive particles, with temperatures between -20°C and +80°C  in standard configurations, and up to 300°C in special versions. This series features both belt-driven(execution 4) and direct drive(execution 1,9,12) versions, suitable for applications with high airflow  and medium  pressure.</p>
<p>Airflow: up to 42 000 m<sup>3</sup>/h<br />
Max static pressure buildup: 5 500 Pa<br />
Max operating temperature: 80°C</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<p><a href="https://www.dynair.hu/termek/dynair-ps-l-at-inox-backward-curved-blade-centrifugal-fans-for-dusty-air/" target="_blank" rel="noopener">PS-L/AT</a> high temp version<br />
<a href="https://www.dynair.hu/termek/dynair-ps-l-inox-backward-curved-blade-centrifugal-fans-for-dusty-air/" target="_blank" rel="noopener">PS-L/INOX</a> stainless steel version<br />
<a href="https://www.dynair.hu/termek/dynair-ps-l-at-inox-backward-curved-blade-centrifugal-fans-for-dusty-air/" target="_blank" rel="noopener">PS-L ATX</a> ATEX version</p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/PS-L-catalogue.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-ps-l-backward-curved-blade-centrifugal-fans-for-dusty-air/">Dynair PS-L Backward curved blade centrifugal fans for dusty air</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Volute casing made out of steel sheet, protected against atmospheric agenty by epoxy paint.</li>
<li>Aerodynamically shaped inlet cone, made from steel sheet, covered in epoxy paint.</li>
<li>Single inlet, high efficiency  backward-curved steel impeller. Class 3 versions are suited for operation at high speed.</li>
<li>For executions 1,9,12, a cast iron mono-block support is used, with ball bearings, designed for easy lubrication. Pulleys, belts, motor support and belt protection guard supplied as standard.</li>
<li>Asynchronous three-phase motors, with IP55 Class F protection, CE marked, compliant with the following standards: IEC 60034, IEC 60072, EMC 2004=108/CE, LVD 2006/95/CE. Suitable for S1 service (continuous operation at constant load).</li>
</ul>
<p><strong>Accessoreies:</strong></p>
<ul>
<li>Condensation drain hole (TS)</li>
<li>Inspection door (PI)</li>
<li>Inlet counter flange(CFA)</li>
<li>Outlet counter flange(CFP)</li>
<li>Inlet protection guard(RA)</li>
<li>Outlet protection guard(RP)</li>
<li>Inlet flexible connector(GA)</li>
<li>Outlet flexible connector(GP)</li>
<li>Inlet vane control</li>
<li>Outlet setting shutter</li>
<li>Anti-vibration mounts</li>
</ul>
<p><strong>Special versions:</strong></p>
<ul>
<li><a href="https://www.dynair.hu/termek/dynair-ps-l-at-inox-backward-curved-blade-centrifugal-fans-for-dusty-air/" target="_blank" rel="noopener">High temperature version</a>, suitable for conveying hot gases (up to 150°C or 300°C)
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See:<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/high-temperature-fans-200c/" target="_blank" rel="noopener">High temperature fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-ps-l-inox-backward-curved-blade-centrifugal-fans-for-dusty-air/" target="_blank" rel="noopener">Corrosion resistant version</a>, featuring an AISI 304 stainles steel casing, inlet and impeller
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See:<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/anticorrosion-fans/" target="_blank" rel="noopener">Anticorrosion fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-ps-l-atex-backward-curved-blade-centrifugal-fans-for-dusty-air/" target="_blank" rel="noopener">ATEX version</a>, compliant with Directives 94/9/CE  and 2014/34/EU.
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See:<a href="https://www.dynair.hu/term%C3%A9kkateg%C3%B3ria/atex-fans/" target="_blank" rel="noopener">ATEX Fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-ps-l-backward-curved-blade-centrifugal-fans-for-dusty-air/">Dynair PS-L Backward curved blade centrifugal fans for dusty air</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair PR-Q AT Backward curved blade centrifugal fans for clean air or slightly dusty air with t from 100 to 200°C</title>
		<link>https://www.dynair.hu/termek/dynair-pr-q-at-backward-curved-blade-centrifugal-fans-for-clean-air-or-slightly-dusty-air-with-t-from-100-to-200c/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:13 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8163/</guid>

					<description><![CDATA[<p>The PR-Q series of fans are designed  for industrial or commercial applications, for heating, ventilation, air-conditioning, or filtering in large estabilishments. PRL fans can convey clean air, smoke or even slightly dusty air with temperatures between +100°C and +200°C  in standard configurations, and up to 300°C in special versions. The main characteristic of the PR-Q series is the rectangular construction, which allows the fan to be positioned in four different orientations (0°-90°-180°-270°) without any additional components. The lack of protruding motor support allows for a more compact design. Available in 6 sizes.</p>
<p>Airflow: up to 9 100 m<sup>3</sup>/h<br />
Max static pressure buildup:  990 Pa<br />
Max operating temperature: 100°C</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<p><a href="https://www.dynair.hu/termek/dynair-pr-q-ht-backward-curved-centrifugal-fans-f400/" target="_blank" rel="noopener">PR-Q HT</a> version for smoke extraction</p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/PRQ-AT-catalogue.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/PRQ-AT-accessories.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-pr-q-at-backward-curved-blade-centrifugal-fans-for-clean-air-or-slightly-dusty-air-with-t-from-100-to-200c/">Dynair PR-Q AT Backward curved blade centrifugal fans for clean air or slightly dusty air with t from 100 to 200°C</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Volute casing with rectangular frame, made from galvanized steel sheet, coated in epoxy.</li>
<li>Single inlet, high efficiency backward-curved galvanized steel impeller with a die-cast aluminium hub.</li>
<li>Only available in Execution 5, with impeller coupled directly to the flanged motor. (Rotation:RD)</li>
<li>Asynchronous three-phase motor, with IP55 grade protection and Class F insulation, CE marked, compliant with the following standards: IEC 60034, IEC 60072, EMC 2004=108/CE, LVD 2006/95/CE. Suitable for S1 service (continuous operation at constant load).</li>
</ul>
<p><strong>Upon request:</strong></p>
<ul>
<li><a href="https://www.dynair.hu/termek/dynair-pr-q-ht-backward-curved-centrifugal-fans-f400/" target="_blank" rel="noopener">HT version for fire smoke extraction</a>, compliant with EN 12101-3 standard.
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%C3%A9kkateg%C3%B3ria/smoke-and-heat-extract-fans-and-fire-fighting-systems/smoke-extract-fans/" target="_blank" rel="noopener">Smoke extraction fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li>PR-Q AT 2 speed version with a double polarity motor.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Inlet and outlet protection guard manufactured according to UNI 12499 standard and protected against atmospheric agents.</li>
<li>Inlet/outlet flexible connectors</li>
<li>Anti-vibration supports</li>
<li>Inlet/outlet counter flange</li>
<li>Speed controller (available in  autotransformer or inverter version)</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-pr-q-at-backward-curved-blade-centrifugal-fans-for-clean-air-or-slightly-dusty-air-with-t-from-100-to-200c/">Dynair PR-Q AT Backward curved blade centrifugal fans for clean air or slightly dusty air with t from 100 to 200°C</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair TACC compact axial roof fans</title>
		<link>https://www.dynair.hu/termek/dynair-tacc-compact-axial-roof-fans/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:10 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8113/</guid>

					<description><![CDATA[<p>Thes TACC series of axial roof fans are suited for extracting larger volumes of air, than their radial counterparts. therefore, they are particulalry ideal for air extraction of large volume premises, such as industrial plants. The main features of the TACC series fans, are their robust construction, easy installation and maintenance, and high efficiency; thanks in large part to their axial impeller with aeorfoil profile blades. These fans are suitable for direct or ducted extraction of clean air, and even available in reverse flow configurations, with an air intake.  Designed to operate between -15°C and +50°C, featuring variable pitch blades. Available in 8 different sizes, with diamaters ranging from 900 to 1600 mm.</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<h3><a href="https://www.dynair.hu/wp-content/uploads/2021/05/TACC.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>&#160;</p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-tacc-compact-axial-roof-fans/">Dynair TACC compact axial roof fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel.</li>
<li>Outer casing made from steel sheet, with an epoxy coating.</li>
<li>Axial impeller with aerofoil profile blades made from reinforced plastic, with an aluminium hub. Complete assembly balanced according to ISO 1940 standards.</li>
<li>Impeller blade pitch can be manually adjusted, when the device is off.</li>
<li>Weatherproof upper cover made from ABS plastic (models 400-630) or multilayer fiberglass (models 710-900).</li>
<li>Airflow from motor to impeller.</li>
<li>Weatherproof steel rod protection guard on inlet side, manufactured according to UNI 10615 regulations.</li>
<li>Asynchronous three-phase motor, suitable for S1 service (continuous operation at constant load), with IP55 grade protection and Class F insulation,  CE marked, in compliance with the following international standards: IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE.</li>
</ul>
<p><strong>Accessories: </strong></p>
<ul>
<li>Inlet gravity shutter (SA)</li>
<li>Counter-base to be walled up (CB)</li>
<li>Support base and reduction (BA and RD)</li>
<li>Acoustically insulated support base (PB)</li>
<li>Motor side protection guard (CCrc)</li>
</ul>
<p><strong>Available options:</strong></p>
<ul>
<li>Aluminium upper cover (not available fo the TACC 900 model)</li>
<li>Aluminium impeller</li>
<li>Reverse flow version</li>
<li>Three-phase double polarity motor version</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-tacc-compact-axial-roof-fans/">Dynair TACC compact axial roof fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair CCB bifurcated ducted axial fans</title>
		<link>https://www.dynair.hu/termek/dynair-ccb-bifurcated-ducted-axial-fans/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:10 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8146/</guid>

					<description><![CDATA[<p>The bifurcated CCB fans are designed to convey hot smoke, fumes and vapours of fluids, or air saturated by grease, oil or particles, where the motor has to be totally separated from the airflow. This is possible thanks to the motor being enclosed in a completely isolated pod, behind the impeller.  For example, they can be used in professional kitchens, painting booths, furnaces, foundries, cooling/evaporative towers, etc. Their design allows for easy installation and maintenance. The casing is double ended with standard flanges, allowing for installation either along the ducting or at both ends. The fans of the CCB series are designed to convey air with a temperatures  up to +200°C in continuous "S1" service at constant load.</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/CCB-CONSTRUCTION.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/CCB-ACCESSORIES.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-ccb-bifurcated-ducted-axial-fans/">Dynair CCB bifurcated ducted axial fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Stainless steel AISI 304 casing, with airtight motor housing, featuring fixing flanges manufactured according to ISO 13351 standards.</li>
<li>High performance axial impeller with aerofoil profile blades and hub made from die cast aluminium, balanced according to the ISO 1940 standard. The pitch angle of the blades can be adjusted when stationary.</li>
<li>Impeller coupled directly to the motor, with airflow from impeller to motor.</li>
<li>Asynchronous single- or three-phase motor, suitable for S1 service (coninuous operation at constant load) with IP55 grade protection, Class F insulation, CE marked, in compliance with the following international standards: IEC 60034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Flat protection guard (CCr)</li>
<li>Flexible noise-cancelling connectors (CCga)</li>
<li>Support feet (CCst)</li>
<li>Inlet/outlet bell mouth (CCbo)</li>
<li>Silencers, with or without pod, in three lengths (CCsa or CCsb)</li>
<li>Counter flange (CCf)</li>
<li>Counter flange with collar (CCfc)</li>
<li>Anti-vibration mounts</li>
</ul>
<p>Epoxy painted case available upon request.</p>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-ccb-bifurcated-ducted-axial-fans/">Dynair CCB bifurcated ducted axial fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair S-CUBE KAT Backward curve centrifugal box fans &#8211; High temperature for industrial kitchens</title>
		<link>https://www.dynair.hu/termek/dynair-s-cube-kat-backward-curve-centrifugal-box-fans-high-temperature-for-industrial-kitchens/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:09 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8137/</guid>

					<description><![CDATA[<p>These fans are the special, high temp versions of the <a href="https://www.dynair.hu/termek/dynair-s-cube-backward-curved-centrifugal-box-fans/" target="_blank" rel="noopener">S-CUBE</a> series, specifically designed for the ventilation of industrial kitchens. The motor is completely isolated from the airflow, allowing for the extraction of hot gases from +100°C to +180°C without the need for frequent cleaning or maintenance, even dirty, greasy air or smoke can be easily conveyed with this device. The double-layer, acoustically insulated panels reduce noise, making these devices ideal for indoor installation, featuring a backward curved impeller and speed regulation via a self-transformer controller.</p>
<p>Airflow: up to 12 000 m<sup>3</sup>/h<br />
Max static pressure rise: 740 Pa.<br />
Max operating temperature: 180 °C</p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/SCUBE-KAT-catalogue.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/SCUBE-KAT-accessories.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-s-cube-kat-backward-curve-centrifugal-box-fans-high-temperature-for-industrial-kitchens/">Dynair S-CUBE KAT Backward curve centrifugal box fans &#8211; High temperature for industrial kitchens</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Aluminium frame with double-layer acoustically insulated panels made from self-extinguishing material, removable from the impeller side.</li>
<li>Asynchronous single,- or three-phase squirrel cage motors in B5 standard shape, outside the path of airflow. Equipped with IP55 grade protection and class F insulation, the motors are CE marked, and compliant with the following international standards: IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE. Suitable for continuous operation at constant load.</li>
<li>Backward curved blade impeller, made from galvanized steel sheet, balanced according to the ISO 1940 standard.</li>
<li>Integrated mounting points for easy handling and installation.</li>
<li>Suitable for both vertical or horizontal installation, an optionally available waterproof cover is recommended for outdoor installations.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Waterproof protection cover</li>
<li>Anti-vibration mounts</li>
<li>Support feet for floor installation</li>
<li>Round spigot inlet cone</li>
<li>Square to rount outlet adapter</li>
<li>Flexible connector</li>
<li>IP67 service switch</li>
<li>Grease collector tray</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-s-cube-kat-backward-curve-centrifugal-box-fans-high-temperature-for-industrial-kitchens/">Dynair S-CUBE KAT Backward curve centrifugal box fans &#8211; High temperature for industrial kitchens</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair FC/FC-2V AT Single-or dual-speed centrifugal roof fans for hot air</title>
		<link>https://www.dynair.hu/termek/dynair-fc-fc-2v-at-single-or-dual-speed-centrifugal-roof-fans-for-hot-air/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:09 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8124/</guid>

					<description><![CDATA[<p>These fans are the special, high temp versions of the <a href="https://www.dynair.hu/termek/dynair-fc-single-speed-centrifugal-roof-fans-with-horizontal-discharge/" target="_blank" rel="noopener">FC</a> and <a href="https://www.dynair.hu/termek/dynair-fc-2v-dual-speed-centrifugal-roof-fans-with-horinzontal-discharge/" target="_blank" rel="noopener">FC-2V</a> series of centrifugal roof fans, specially designed for continuous extraction of clean air between +100°C and +200°C. These fans feature horizontal discharge, with the FC AT being the simpler, single-speed and FC-2V AT the dual-speed version featuring a double-polarity motor.</p>
<p>Airflow: up to 17 000 m<sup>3</sup>/h<br />
Max static pressure rise: 740 Pa<br />
Max temperature in continuous operation: 200°C</p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC-AT-AT2V-catalogue.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fc-fc-2v-at-single-or-dual-speed-centrifugal-roof-fans-for-hot-air/">Dynair FC/FC-2V AT Single-or dual-speed centrifugal roof fans for hot air</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel.</li>
<li>Inlet protection guard made from steel rods, covered in a weatherproof coating, all according to UNI 12499 regulations.</li>
<li>High efficiency, low noise, backward curved blade impeller made from galvanized steel sheet, statically and dynamically balanced statically and dynamically according to ISO 1940 standards.</li>
<li>Aluminium upper cover, featuring cooling slots for the motor.</li>
<li>Asynchronous single- or three-phase motor, CE marked, with IP55 protection and Class F insulation,  manufactured according to the following international standards: IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE. Suitable for S1 Service (continuous operation at constant load).</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Backdraught gravity shutters(TS)</li>
<li>Silencer(GR)</li>
<li>Counter base to be walled up (CB)</li>
<li>Support base for corrugated roofs (BA)</li>
<li>Inlet protection guard(RA)</li>
<li>Service switch</li>
<li>Acoustically insulated support base(PB)</li>
<li>Flat protection guard (CCr)</li>
</ul>
<p><strong>Available upon request:</strong></p>
<ul>
<li><a href="https://www.dynair.hu/termek/dynair-fc-ht-centrifugal-roof-fans-f400/" target="_blank" rel="noopener">HT version</a>: High temperature version for emregency smoke extraction in case of fire (F400).
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/smoke-and-heat-extract-fans-and-fire-fighting-systems/smoke-extract-fans/" target="_blank" rel="noopener">Smoke extraction fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-fc-fcv-atex-single-speed-centrifugal-roof-fans/" target="_blank" rel="noopener">ATEX version</a>: ATEX certified version, compliant with directives 94/9/CE and 2014/34/UE.
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/atex-fans/" target="_blank" rel="noopener">ATEX Fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fc-fc-2v-at-single-or-dual-speed-centrifugal-roof-fans-for-hot-air/">Dynair FC/FC-2V AT Single-or dual-speed centrifugal roof fans for hot air</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair DIC AT Forward curved blade centrifugal fans for air temperature up to +150°C</title>
		<link>https://www.dynair.hu/termek/dynair-dic-at-forward-curved-blade-centrifugal-fans-for-air-temperature-up-to-150c/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:09 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8128/</guid>

					<description><![CDATA[<h4>Construction</h4>
<ul>
<li>Volute casing in steel sheet, protected against atmospheric agents by epoxy paint</li>
<li>Single inlet, single width forward curved impeller (sirocco type), in galvanized steel sheet</li>
<li>Execution 5 (with impeller directly coupled to flanged motor)</li>
<li>Standard orientation LG270°</li>
<li>Asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, B35 shape. DIC 100 T and M with motor shape B14, IP44, class B.</li>
</ul>
<h4>Accessories</h4>
<ul>
<li>Inlet and outlet protection guard according to UNI 12499 rules and protected against atmospheric agents</li>
<li>Motor support in steel sheet epoxy painted.</li>
</ul>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08//DIC-AT-catalogue.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-dic-at-forward-curved-blade-centrifugal-fans-for-air-temperature-up-to-150c/">Dynair DIC AT Forward curved blade centrifugal fans for air temperature up to +150°C</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>The centrifugal fans of the DIC series are designed to convey clean and not-dusty air and smoke with temperature range from 100°C to 150°C. They<br />
are suitable for all the industrial applications where small air volumes and high pressures are required.</h4>
<p>The series consists of different models with impeller diameter from 100 to 180 mm. The motor is directly fitted to the forward curved impeller. The casing is easily adjustable, also on site, to the required discharge angle every 45°, including 180° and 225° position.</p>
<p><strong>upon request:</strong></p>
<ul>
<li>Rotation RD upon request</li>
</ul>
<p><strong>Versions:</strong></p>
<ul>
<li>DIC ATEX and DIC INOX ATEX versions according to Directives 94/9/CE and 2014/34/UE</li>
<li>DIC INOX: corrosion resistance version, with casing, flanges and impeller in stainless steel AISI 304</li>
</ul>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-dic-at-forward-curved-blade-centrifugal-fans-for-air-temperature-up-to-150c/">Dynair DIC AT Forward curved blade centrifugal fans for air temperature up to +150°C</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
