<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Centrifugal roof fans &#8211; Dynair.hu</title>
	<atom:link href="https://www.dynair.hu/term%C3%A9kkateg%C3%B3ria/industrial-and-building-ventilation-fans-standard-air/centrifugal-roof-fans/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.dynair.hu</link>
	<description>Dynair ventilation</description>
	<lastBuildDate>Tue, 23 Aug 2022 07:42:09 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.dynair.hu/wp-content/uploads/2022/01/favicon.jpg</url>
	<title>Centrifugal roof fans &#8211; Dynair.hu</title>
	<link>https://www.dynair.hu</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Dynair FCP-V single-speed centrifugal roof fans with vertical discharge</title>
		<link>https://www.dynair.hu/termek/dynair-fcp-v-single-speed-centrifugal-roof-fans-vertical-discharge/</link>
		
		<dc:creator><![CDATA[Péter Komár]]></dc:creator>
		<pubDate>Fri, 17 Jun 2022 10:27:12 +0000</pubDate>
				<guid isPermaLink="false">https://www.dynair.hu/?post_type=product&#038;p=12593</guid>

					<description><![CDATA[<div class="innerbox">
<p>The FCP-V line is our latest series of high performance centrifugal roof fans, with vertical discharge, suitable for direct or ducted extraction in residential, commercial, or even industrial applications. The backward curved blades provide great airflow while maintaining low noise level. The device is suitable for use with clean or slightly dusty air, in temperatures between -20 and +80°C. Available in multiple different sizes, ranging from 800 to 1600 mm in diameter.</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
</div>
<p><strong>Versions:</strong><br />
<a href="https://www.dynair.hu/termek/dynair-fcp-single-speed-centrifugal-roof-fans-with-horizontal-discharge/" target="_blank" rel="noopener">FCP with horizontal discharge</a><br />
<a href="https://www.dynair.hu/termek/dynair-fcp-atex-fcp-v-atex-single-speed-centrifugal-roof-fans/" target="_blank" rel="noopener">FCP-V ATEX for explosive environments</a></p>
<h3><a href="https://www.dynair.hu/wp-content/uploads/2022/06/FCP-V-19-5-21.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC-FCV-ACCESSORIES.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fcp-v-single-speed-centrifugal-roof-fans-vertical-discharge/">Dynair FCP-V single-speed centrifugal roof fans with vertical discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel.</li>
<li>Protection guard made from sqaure micro-pressed steel sheet, protected against the elements (model 350 features a guard made out of drawn steel wire). Manufactured according to the EN ISO 12499 standard.</li>
<li>High efficiency, backward curved blade impeller made from galvanized steel sheet, with low noise levels, statically and dynamically balanced statically and dynamically according to ISO 1940 standard.</li>
<li>Upper cover made out of ABS plastic, with appropriate cooling slots for the motor.</li>
</ul>
<p><strong>Motor:        </strong></p>
<ul>
<li>Asynchronous single- or three-phase motor, CE marked, with IP55 grade protection and Class F insulation,  manufactured according to the following international standards: IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE.</li>
<li>Suitable for S1 Service (continuous operation at constant load).</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Backdraught gravity shutter (TS)</li>
<li>Silencer (GR)</li>
<li>Counterbase (CB)</li>
<li>Mounting plate for corrugated roofs (BA)</li>
<li>Inlet protection guard (RA)</li>
<li>Service switch</li>
<li>Acoustically insulated support base(PB)</li>
<li>Flat protection guard (CCr)</li>
</ul>
<p>Also available in a 60Hz version, and an <a href="https://www.dynair.hu/termek/dynair-fcp-atex-fcp-v-atex-single-speed-centrifugal-roof-fans/" target="_blank" rel="noopener">ATEX certified version</a> for potentially flammable or explosive environments (See: <a href="https://www.dynair.hu/term%C3%A9kkateg%C3%B3ria/atex-fans/" target="_blank" rel="noopener">ATEX Fans</a>).</p>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fcp-v-single-speed-centrifugal-roof-fans-vertical-discharge/">Dynair FCP-V single-speed centrifugal roof fans with vertical discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair FCP single-speed centrifugal roof fans with horizontal discharge</title>
		<link>https://www.dynair.hu/termek/dynair-fcp-single-speed-centrifugal-roof-fans-with-horizontal-discharge/</link>
		
		<dc:creator><![CDATA[Péter Komár]]></dc:creator>
		<pubDate>Fri, 17 Jun 2022 09:27:34 +0000</pubDate>
				<guid isPermaLink="false">https://www.dynair.hu/?post_type=product&#038;p=12585</guid>

					<description><![CDATA[<div class="innerbox">
<p>The FCP line is our latest series of high performance centrifugal roof fans, with horizontal discharge, suitable for direct or ducted extraction in residential, commercial, or even industrial applications. The backward curved blades provide great airflow while maintaining low noise level. The device is suitable for use with clean or slightly dusty air, in temperatures between -20 and +80°C. Available in multiple different sizes, ranging from 755 to 1400 mm in diameter.</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
</div>
<p><strong>Versions:</strong><br />
<a href="https://www.dynair.hu/termek/dynair-fcp-v-single-speed-centrifugal-roof-fans-vertical-discharge/" target="_blank" rel="noopener">FCP-V with vertical discharge</a><br />
<a href="https://www.dynair.hu/termek/dynair-fcp-atex-fcp-v-atex-single-speed-centrifugal-roof-fans/" target="_blank" rel="noopener">FCP ATEX for explosive environments</a></p>
<h3><a href="https://www.dynair.hu/wp-content/uploads/2022/06/FCP-19-5-21-Dynair.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC-FCV-ACCESSORIES.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fcp-single-speed-centrifugal-roof-fans-with-horizontal-discharge/">Dynair FCP single-speed centrifugal roof fans with horizontal discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel.</li>
<li>Protection guard made from sqaure micro-pressed steel sheet, protected against the elements (model 350 features a guard made out of drawn steel wire). Manufactured according to the EN ISO 12499 standard.</li>
<li>High efficiency, backward curved blade impeller made from galvanized steel sheet, with low noise levels, statically and dynamically balanced statically and dynamically according to ISO 1940 standard.</li>
<li>Upper cover made out of ABS plastic, with appropriate cooling slots for the motor.</li>
</ul>
<p><strong>Motor:        </strong></p>
<ul>
<li>Asynchronous single- or three-phase motor, CE marked, with IP55 grade protection and Class F insulation,  manufactured according to the following international standards: IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE.</li>
<li>Suitable for S1 Service (continuous operation at constant load).</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Backdraught gravity shutter (TS)</li>
<li>Silencer (GR)</li>
<li>Counterbase (CB)</li>
<li>Support base corrugated roofs (BA)</li>
<li>Inlet protection guard (RA)</li>
<li>Service switch</li>
<li>Acoustically insulated support base(PB)</li>
<li>Flat protection guard (CCr)</li>
</ul>
<p>Also available in a 60Hz version, and an <a href="https://www.dynair.hu/termek/dynair-fcp-atex-fcp-v-atex-single-speed-centrifugal-roof-fans/" target="_blank" rel="noopener">ATEX certified version</a> for potentially flammable or explosive environments (See: <a href="https://www.dynair.hu/term%C3%A9kkateg%C3%B3ria/atex-fans/" target="_blank" rel="noopener">ATEX Fans</a>).</p>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fcp-single-speed-centrifugal-roof-fans-with-horizontal-discharge/">Dynair FCP single-speed centrifugal roof fans with horizontal discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair FCV 2V dual-speed centrifugal roof fans with vertical discharge</title>
		<link>https://www.dynair.hu/termek/dynair-fcv-2v-dual-speed-centrifugal-roof-fans-with-vertical-discharge/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Fri, 27 Jul 2018 06:47:57 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=8714</guid>

					<description><![CDATA[<p>This series of fans features a unique, three-phase motor, with the ability to switch between star and delta configurations, in order to provide two different operating speeds. The motor is outside the path of airflow, allowing  efficient extraction of clean or even slightly dusty air, with temperatures up to 100°C. These fans are suitable for direct or ducted extraction, in residential, commercial, or even industrial applications. Their ingenious design allows for easy installation and smooth, efficient, low noise operation. The <a href="https://www.dynair.hu/termek/dynair-fc-2v-dual-speed-centrifugal-roof-fans-with-horinzontal-discharge/" target="_blank" rel="noopener">FC-2V</a> version features horizontal, the FCV-2V vertical discharge. Available in multiple different sizes; from 650 to 1400mm in diameter.</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC2V-FCV2V-CONSTRUCTION.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC2V-FCV2V-ACCESSORIES.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fcv-2v-dual-speed-centrifugal-roof-fans-with-vertical-discharge/">Dynair FCV 2V dual-speed centrifugal roof fans with vertical discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel.</li>
<li>Protective shroud manufactured from drawn steel rods, compliant with UNI 10615:1997 regulations.</li>
<li>Backward curved blade impeller made from galvanized steel, designed for high efficiency and low noise operation, balanced statically and dynamically according to the ISO 1940 standard.</li>
<li>Asynchronous, double polarity three-phase motor, CE marked,equipped with IP55 grade protection, Class F insulation, compliant with the following standards: IEC 60034, Iec 60072, EMC 2014/30/UE, LVD 2014/35/UE.</li>
<li>Upper cover made from ABS plastic, featuring cooling slots for the motor.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Backdraught gravity shutters (TS)</li>
<li>Silencer(GR)</li>
<li>Mounting plate for corrugated roofs (BA)</li>
<li>Inlet protection guard(RA)</li>
<li>Service switch</li>
<li>Silenced mounting plate (PB)</li>
</ul>
<p><strong>Special versions:</strong></p>
<ul>
<li><a href="https://www.dynair.hu/termek/dynair-fc-at-fc-2v-at-single-or-dpouble-speed-centrifugal-roof-fans-for-air-temperature-up-to-200c/" target="_blank" rel="noopener">AT version</a>:<em> horizontal discharge</em> version, made for constant operation in environmnents with air temperatures up to 200°C).
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/high-temperature-fans-200c/" target="_blank" rel="noopener">High temperature fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-fc-ht-centrifugal-roof-fans-f400/" target="_blank" rel="noopener">HT version</a>: <em>horizontal discharge, single-speed </em>version made for heat and smoke extraction (F400).
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/smoke-and-heat-extract-fans-and-fire-fighting-systems/smoke-extract-fans/" target="_blank" rel="noopener">Smoke extraction fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-fc-fcv-atex-single-speed-centrifugal-roof-fans/" target="_blank" rel="noopener">ATEX version</a>: ATEX certified, <em>single-speed</em> version, compliant with directives 94/9/CE and 2014/34/UE.
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/atex-fans/" target="_blank" rel="noopener">ATEX Fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fcv-2v-dual-speed-centrifugal-roof-fans-with-vertical-discharge/">Dynair FCV 2V dual-speed centrifugal roof fans with vertical discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair FC 2V dual-speed centrifugal roof fans with horinzontal discharge</title>
		<link>https://www.dynair.hu/termek/dynair-fc-2v-dual-speed-centrifugal-roof-fans-with-horinzontal-discharge/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Fri, 27 Jul 2018 06:37:21 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=8712</guid>

					<description><![CDATA[<p>This series of fans features a unique, three-phase motor, with the ability to switch between star and delta configurations, in order to provide two different operating speeds. The motor is outside the path of airflow, allowing  efficient extraction of clean or even slightly dusty air, with temperatures up to 100°C. These fans are suitable for direct or ducted extraction, in residential, commercial, or even industrial applications. Their ingenious design allows for easy installation and smooth, efficient, low noise operation. The FC-2V version features horizontal, the <a href="https://www.dynair.hu/termek/dynair-fcv-2v-double-speed-centrifugal-roof-fans-vertical-discharge/" target="_blank" rel="noopener">FCV-2V</a> vertical discharge. Available in multiple different sizes; from 600 to 1100mm in diameter.</p>
<p>This product complies with the European Union's ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC2V-FCV2V-CONSTRUCTION.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC2V-FCV2V-ACCESSORIES.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fc-2v-dual-speed-centrifugal-roof-fans-with-horinzontal-discharge/">Dynair FC 2V dual-speed centrifugal roof fans with horinzontal discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel.</li>
<li>Protective shroud manufactured from drawn steel rods, compliant with UNI 10615:1997 regulations.</li>
<li>Backward curved blade impeller made from galvanized steel, designed for high efficiency and low noise operation, balanced statically and dynamically according to the ISO 1940 standard.</li>
<li>Asynchronous, double polarity three-phase motor, CE marked,equipped with IP55 grade protection, Class F insulation, compliant with the following standards: IEC 60034, Iec 60072, EMC 2014/30/UE, LVD 2014/35/UE.</li>
<li>Upper cover made from ABS plastic, featuring cooling slots for the motor.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Backdraught gravity shutters (TS)</li>
<li>Silencer(GR)</li>
<li>Mounting plate for corrugated roofs (BA)</li>
<li>Inlet protection guard(RA)</li>
<li>Service switch</li>
<li>Silenced mounting plate (PB)</li>
</ul>
<p><strong>Special versions:</strong></p>
<ul>
<li><a href="https://www.dynair.hu/termek/dynair-fc-at-fc-2v-at-single-or-dpouble-speed-centrifugal-roof-fans-for-air-temperature-up-to-200c/" target="_blank" rel="noopener">AT version</a>: made for constant operation in environmnents with air temperatures up to 200°C)
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/high-temperature-fans-200c/" target="_blank" rel="noopener">High temperature fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-fc-ht-centrifugal-roof-fans-f400/" target="_blank" rel="noopener">HT version</a>: <em>single-speed</em> version made for heat and smoke extraction (F400)
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/smoke-and-heat-extract-fans-and-fire-fighting-systems/smoke-extract-fans/" target="_blank" rel="noopener">Smoke extraction fans</a>)</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-fc-fcv-atex-single-speed-centrifugal-roof-fans/" target="_blank" rel="noopener">ATEX version</a>: ATEX certified, <em>single-speed</em> version, compliant with directives 94/9/CE and 2014/34/UE
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/atex-fans/" target="_blank" rel="noopener">ATEX Fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener"><span style="font-size: 18.6667px;">For further details, feel free to contact KOMPEL Kft.</span></a></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fc-2v-dual-speed-centrifugal-roof-fans-with-horinzontal-discharge/">Dynair FC 2V dual-speed centrifugal roof fans with horinzontal discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair REA centrifugal roof fans with horizontal discharge</title>
		<link>https://www.dynair.hu/termek/dynair-rea-centrifugal-roof-fans-with-horizontal-discharge/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:13 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8155/</guid>

					<description><![CDATA[<p>This  series of  centrifugal roof fans were primarily designed for easy ventilation of residential, commercial or industrial buildings,  suitable for both direct and ducted extraction. They can exhaust clean air up to 40°C. The single- or three-phase external rotor motor allows complete speed regulation, via the additional electronic regulator. The three-phase version also features the ability to choose between delta/star configuration, allowing instantaneous switching between two different operating speeds. Available in multiple different sizes, ranging from 395 to 810mm in diameter. Also available in a vertical discharge configuration (<a href="https://www.dynair.hu/termek/dynair-rev-centrifugal-roof-fans-with-external-rotor-motor-vertical-discharge/" target="_blank" rel="noopener">REV series</a>).</p>
<p>Airflow: up to 3500m<sup>3</sup>/h<br />
Max static pressure buildup: 420 Pa<br />
Max operating temperature: 40°C</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/REA-catalogue.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/REA-accessories.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-rea-centrifugal-roof-fans-with-horizontal-discharge/">Dynair REA centrifugal roof fans with horizontal discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel.</li>
<li>Protection guard made from drawn steel rods, manufactured in compliance with UNI 10615:11997 regulations.</li>
<li>Low noise, highly efficient backward curved blade impeller made from galvanized steel.</li>
<li>Single- or three-phase external rotor motor, tropycalized, equipped with internal thermal protection and IP44 grade ingress protection, with the 20 and 25 models featuring Class B, the 31-40 models Class F insulation.</li>
<li>Upper cover made from aluminium.</li>
</ul>
<p><strong>Accessories: </strong></p>
<ul>
<li>
<ul>
<li>Backdraught gravity shutter</li>
<li>Silencers (GR)</li>
<li>Counter base to be walled up (CB)</li>
<li>Mounting plate for corrugated roof coverings(BA)</li>
<li>Service switch</li>
<li>Speed regulators</li>
<li>Support base with noise and vibration dampening(PB)– not available for the 20 model</li>
<li>Flat protection guard (CCr)</li>
</ul>
</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://kompel.hu/kapcsolat/" target="_blank" rel="noopener nofollow">For any further questions, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-rea-centrifugal-roof-fans-with-horizontal-discharge/">Dynair REA centrifugal roof fans with horizontal discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair FCV single-speed centrifugal roof fans with vertical discharge</title>
		<link>https://www.dynair.hu/termek/dynair-fcv-single-speed-centrifugal-roof-fans-with-vertical-discharge/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:11 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8152/</guid>

					<description><![CDATA[<p>This family of fans are suitable for direct or ducted extraction, in residential, commercial, or industrial applications. Their ingenious design allows for easy installation, and smooth, efficient, low noise operation. The <a href="https://www.dynair.hu/termek/dynair-fc-single-speed-centrifugal-roof-fans-with-horizontal-discharge/" target="_blank" rel="noopener">FC</a> version features horizontal discharge, the FCV version; vertical.<strong> </strong>The motor is outside the path of the airflow,  allowing  efficient extraction of clean or even slightly dusty air, with temperatures up to 100°C. These fans feature a single- or three phase motor and backward curved blade impeller. Available in 10 sizes, from 650 to 1400mm in diameter.</p>
<p>Also available in a dual-speed version (<a href="https://www.dynair.hu/termek/dynair-fcv-2v-dual-speed-centrifugal-roof-fans-with-vertical-discharge/" target="_blank" rel="noopener">FCV-2V</a>), featuring a three phase motor with star/delta configuration switchability.</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC-FCV-CONSTRUCTION.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC-FCV-ACCESSORIES.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fcv-single-speed-centrifugal-roof-fans-with-vertical-discharge/">Dynair FCV single-speed centrifugal roof fans with vertical discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel.</li>
<li>Protective shroud manufactured from drawn steel rods, compliant with UNI 10615:1997 regulations.</li>
<li>High efficiency, low noise, backward curved blade impeller made from galvanized steel sheet, statically and dynamically balanced statically and dynamically according to the  ISO 1940 standard.</li>
<li>Asynchronous single- or three-phase motor, CE marked, with IP55 protection and Class F insulation,  manufactured according to the following international standards: IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE.  Suitable for S1 Service (continuous operation at constant load).</li>
<li>Upper cover made from ABS plastic, featuring cooling slots for the motor.</li>
<li>Outer deflector made from high-strength ABS.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Backdraught gravity shutters(TS)</li>
<li>Silencer(GR)</li>
<li>Mounting plate for corrugated roofs (BA)</li>
<li>Inlet protection guard(RA)</li>
<li>Service switch</li>
<li>Acoustically insulated support base(PB)</li>
</ul>
<p><strong>Special versions:</strong></p>
<ul>
<li><a href="https://www.dynair.hu/termek/dynair-fc-at-fc-2v-at-single-or-dpouble-speed-centrifugal-roof-fans-for-air-temperature-up-to-200c/" target="_blank" rel="noopener">AT version</a>: <span style="text-decoration: underline;"><em>Horizontal discharge</em></span> version, suitable for conveying hot air in continuous service.(up to 200°C).
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/high-temperature-fans-200c/" target="_blank" rel="noopener">High temperature fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-fc-ht-centrifugal-roof-fans-f400/" target="_blank" rel="noopener">HT version</a>: High temperature, <span style="text-decoration: underline;"><em>horizontal discharge</em></span> version for emregency smoke extraction in case of fire.
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/smoke-and-heat-extract-fans-and-fire-fighting-systems/smoke-extract-fans/" target="_blank" rel="noopener">Smoke extraction fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-fc-fcv-atex-single-speed-centrifugal-roof-fans/" target="_blank" rel="noopener">ATEX version</a>: ATEX certified version,  compliant with directives 94/9/CE and 2014/34/UE.
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/atex-fans/" target="_blank" rel="noopener">ATEX Fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fcv-single-speed-centrifugal-roof-fans-with-vertical-discharge/">Dynair FCV single-speed centrifugal roof fans with vertical discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair REV centrifugal roof fans with vertical discharge</title>
		<link>https://www.dynair.hu/termek/dynair-rev-centrifugal-roof-fans-with-external-rotor-motor-vertical-discharge/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:11 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8153/</guid>

					<description><![CDATA[<p>This  series of centrifugal roof fans were primarily designed for easy ventilation of residential, commercial or industrial buildings,  suitable for both direct and ducted extraction. They can exhaust clean air up to 40°C. The single- or three-phase external rotor motor allows complete speed regulation, via the additional electronic regulator. The three-phase version also features the ability to choose between delta/star configuration, allowing instantaneous switching between two different operating speeds. Available in multiple different sizes, ranging from 650 to 980mm in diameter. Also available in a horizontal discharge configuration (<a href="https://www.dynair.hu/termek/dynair-rea-centrifugal-roof-fans-with-horizontal-discharge/" target="_blank" rel="noopener">REA series</a>).</p>
<p>Airflow: up to 3500m<sup>3</sup>/h<br />
Max static pressure buildup: 420 Pa<br />
Max operating temperature: 40°C</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/REV-catalogue.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/REV-accessories.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-rev-centrifugal-roof-fans-with-external-rotor-motor-vertical-discharge/">Dynair REV centrifugal roof fans with vertical discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel.</li>
<li>Protection guard made from drawn steel rods, manufactured in compliance with UNI 10615:11997 regulations.</li>
<li>Low noise, highly efficient backward curved blade impeller made from galvanized steel.</li>
<li>Single- or three-phase external rotor motor, tropycalized, equipped with internal thermal protection and IP44 grade ingress protection, with the 25 model featuring Class B, the 31-40 models Class F insulation.</li>
<li>Outer deflector made from ABS plastic.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Backdraught gravity shutter</li>
<li>Silencers (GR)</li>
<li>Counter base to be walled up (CB)</li>
<li>Mounting plate for corrugated roof coverings(BA)</li>
<li>Service switch</li>
<li>Speed regulators</li>
<li>Support base with noise and vibration dampening(PB)</li>
<li>Flat protection guard (CCr)</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-rev-centrifugal-roof-fans-with-external-rotor-motor-vertical-discharge/">Dynair REV centrifugal roof fans with vertical discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair FC single-speed centrifugal roof fans with horizontal discharge</title>
		<link>https://www.dynair.hu/termek/dynair-fc-single-speed-centrifugal-roof-fans-with-horizontal-discharge/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:11:36 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8154/</guid>

					<description><![CDATA[<p>This series  of fans are suitable for direct or ducted extraction, in residential, commercial, or industrial applications. Their ingenious design allows for easy installation, and smooth, efficient, low noise operation. The FC version features horizontal discharge, while the <a href="https://www.dynair.hu/termek/dynair-fcv-single-speed-centrifugal-roof-fans-vertical-discharge/" target="_blank" rel="noopener">FCV version</a>; vertical.<strong> </strong>The motor is outside the path of the airflow,  allowing  efficient extraction of clean or even slightly dusty air, with temperatures up to 100°C. These fans feature a one- or three-phase motor and a backward curved blade impeller. Available in 10 sizes; from 600 to 1100mm in diameter.</p>
<p>Also available in a dual-speed version (<a href="https://www.dynair.hu/termek/dynair-fc-2v-dual-speed-centrifugal-roof-fans-with-horinzontal-discharge/" target="_blank" rel="noopener">FC-2V</a>), featuring a three phase motor with star/delta configuration switchability.</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC-FCV-CONSTRUCTION.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC-FCV-ACCESSORIES.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fc-single-speed-centrifugal-roof-fans-with-horizontal-discharge/">Dynair FC single-speed centrifugal roof fans with horizontal discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel.</li>
<li>Protective shroud manufactured from drawn steel rods, compliant with UNI 10615:1997 regulations.</li>
<li>High efficiency, low noise, backward curved blade impeller made from galvanized steel sheet, statically and dynamically balanced statically and dynamically according to ISO 1940 standards.</li>
<li>Asynchronous single- or three-phase motor, CE marked, with IP55 protection and Class F insulation,  manufactured according to the following international standards: IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE. Suitable for S1 Service (continuous operation at constant load).</li>
<li>Upper cover made from ABS plastic, featuring cooling slots for the motor.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Backdraught gravity shutters(TS)</li>
<li>Silencer(GR)</li>
<li>Support base for corrugated roofs (BA)</li>
<li>Inlet protection guard(RA)</li>
<li>Service switch</li>
<li>Acoustically insulated support base(PB)</li>
<li>Aluminium cover</li>
</ul>
<p><strong>Special versions:</strong></p>
<ul>
<li><a href="https://www.dynair.hu/termek/dynair-fc-at-fc-2v-at-single-or-dpouble-speed-centrifugal-roof-fans-for-air-temperature-up-to-200c/" target="_blank" rel="noopener">AT version</a>: Suitable for conveying hot air in continuous service (up to 200°C).
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/high-temperature-fans-200c/" target="_blank" rel="noopener">High temperature fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-fc-ht-centrifugal-roof-fans-f400/" target="_blank" rel="noopener">HT version</a>: High temperature version for emregency smoke extraction in case of fire (F400).
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/smoke-and-heat-extract-fans-and-fire-fighting-systems/smoke-extract-fans/" target="_blank" rel="noopener">Smoke extraction fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-fc-fcv-atex-single-speed-centrifugal-roof-fans/" target="_blank" rel="noopener">ATEX version</a>: ATEX certified version, compliant with directives 94/9/CE and 2014/34/UE.
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/atex-fans/" target="_blank" rel="noopener">ATEX Fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fc-single-speed-centrifugal-roof-fans-with-horizontal-discharge/">Dynair FC single-speed centrifugal roof fans with horizontal discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
