<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Industrial and building ventilation fans &#8211; Standard air &#8211; Dynair.hu</title>
	<atom:link href="https://www.dynair.hu/term%C3%A9kkateg%C3%B3ria/industrial-and-building-ventilation-fans-standard-air/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.dynair.hu</link>
	<description>Dynair ventilation</description>
	<lastBuildDate>Tue, 23 Aug 2022 07:42:09 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.dynair.hu/wp-content/uploads/2022/01/favicon.jpg</url>
	<title>Industrial and building ventilation fans &#8211; Standard air &#8211; Dynair.hu</title>
	<link>https://www.dynair.hu</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Dynair FCP-V single-speed centrifugal roof fans with vertical discharge</title>
		<link>https://www.dynair.hu/termek/dynair-fcp-v-single-speed-centrifugal-roof-fans-vertical-discharge/</link>
		
		<dc:creator><![CDATA[Péter Komár]]></dc:creator>
		<pubDate>Fri, 17 Jun 2022 10:27:12 +0000</pubDate>
				<guid isPermaLink="false">https://www.dynair.hu/?post_type=product&#038;p=12593</guid>

					<description><![CDATA[<div class="innerbox">
<p>The FCP-V line is our latest series of high performance centrifugal roof fans, with vertical discharge, suitable for direct or ducted extraction in residential, commercial, or even industrial applications. The backward curved blades provide great airflow while maintaining low noise level. The device is suitable for use with clean or slightly dusty air, in temperatures between -20 and +80°C. Available in multiple different sizes, ranging from 800 to 1600 mm in diameter.</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
</div>
<p><strong>Versions:</strong><br />
<a href="https://www.dynair.hu/termek/dynair-fcp-single-speed-centrifugal-roof-fans-with-horizontal-discharge/" target="_blank" rel="noopener">FCP with horizontal discharge</a><br />
<a href="https://www.dynair.hu/termek/dynair-fcp-atex-fcp-v-atex-single-speed-centrifugal-roof-fans/" target="_blank" rel="noopener">FCP-V ATEX for explosive environments</a></p>
<h3><a href="https://www.dynair.hu/wp-content/uploads/2022/06/FCP-V-19-5-21.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC-FCV-ACCESSORIES.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fcp-v-single-speed-centrifugal-roof-fans-vertical-discharge/">Dynair FCP-V single-speed centrifugal roof fans with vertical discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel.</li>
<li>Protection guard made from sqaure micro-pressed steel sheet, protected against the elements (model 350 features a guard made out of drawn steel wire). Manufactured according to the EN ISO 12499 standard.</li>
<li>High efficiency, backward curved blade impeller made from galvanized steel sheet, with low noise levels, statically and dynamically balanced statically and dynamically according to ISO 1940 standard.</li>
<li>Upper cover made out of ABS plastic, with appropriate cooling slots for the motor.</li>
</ul>
<p><strong>Motor:        </strong></p>
<ul>
<li>Asynchronous single- or three-phase motor, CE marked, with IP55 grade protection and Class F insulation,  manufactured according to the following international standards: IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE.</li>
<li>Suitable for S1 Service (continuous operation at constant load).</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Backdraught gravity shutter (TS)</li>
<li>Silencer (GR)</li>
<li>Counterbase (CB)</li>
<li>Mounting plate for corrugated roofs (BA)</li>
<li>Inlet protection guard (RA)</li>
<li>Service switch</li>
<li>Acoustically insulated support base(PB)</li>
<li>Flat protection guard (CCr)</li>
</ul>
<p>Also available in a 60Hz version, and an <a href="https://www.dynair.hu/termek/dynair-fcp-atex-fcp-v-atex-single-speed-centrifugal-roof-fans/" target="_blank" rel="noopener">ATEX certified version</a> for potentially flammable or explosive environments (See: <a href="https://www.dynair.hu/term%C3%A9kkateg%C3%B3ria/atex-fans/" target="_blank" rel="noopener">ATEX Fans</a>).</p>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fcp-v-single-speed-centrifugal-roof-fans-vertical-discharge/">Dynair FCP-V single-speed centrifugal roof fans with vertical discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair FCP single-speed centrifugal roof fans with horizontal discharge</title>
		<link>https://www.dynair.hu/termek/dynair-fcp-single-speed-centrifugal-roof-fans-with-horizontal-discharge/</link>
		
		<dc:creator><![CDATA[Péter Komár]]></dc:creator>
		<pubDate>Fri, 17 Jun 2022 09:27:34 +0000</pubDate>
				<guid isPermaLink="false">https://www.dynair.hu/?post_type=product&#038;p=12585</guid>

					<description><![CDATA[<div class="innerbox">
<p>The FCP line is our latest series of high performance centrifugal roof fans, with horizontal discharge, suitable for direct or ducted extraction in residential, commercial, or even industrial applications. The backward curved blades provide great airflow while maintaining low noise level. The device is suitable for use with clean or slightly dusty air, in temperatures between -20 and +80°C. Available in multiple different sizes, ranging from 755 to 1400 mm in diameter.</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
</div>
<p><strong>Versions:</strong><br />
<a href="https://www.dynair.hu/termek/dynair-fcp-v-single-speed-centrifugal-roof-fans-vertical-discharge/" target="_blank" rel="noopener">FCP-V with vertical discharge</a><br />
<a href="https://www.dynair.hu/termek/dynair-fcp-atex-fcp-v-atex-single-speed-centrifugal-roof-fans/" target="_blank" rel="noopener">FCP ATEX for explosive environments</a></p>
<h3><a href="https://www.dynair.hu/wp-content/uploads/2022/06/FCP-19-5-21-Dynair.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC-FCV-ACCESSORIES.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fcp-single-speed-centrifugal-roof-fans-with-horizontal-discharge/">Dynair FCP single-speed centrifugal roof fans with horizontal discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel.</li>
<li>Protection guard made from sqaure micro-pressed steel sheet, protected against the elements (model 350 features a guard made out of drawn steel wire). Manufactured according to the EN ISO 12499 standard.</li>
<li>High efficiency, backward curved blade impeller made from galvanized steel sheet, with low noise levels, statically and dynamically balanced statically and dynamically according to ISO 1940 standard.</li>
<li>Upper cover made out of ABS plastic, with appropriate cooling slots for the motor.</li>
</ul>
<p><strong>Motor:        </strong></p>
<ul>
<li>Asynchronous single- or three-phase motor, CE marked, with IP55 grade protection and Class F insulation,  manufactured according to the following international standards: IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE.</li>
<li>Suitable for S1 Service (continuous operation at constant load).</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Backdraught gravity shutter (TS)</li>
<li>Silencer (GR)</li>
<li>Counterbase (CB)</li>
<li>Support base corrugated roofs (BA)</li>
<li>Inlet protection guard (RA)</li>
<li>Service switch</li>
<li>Acoustically insulated support base(PB)</li>
<li>Flat protection guard (CCr)</li>
</ul>
<p>Also available in a 60Hz version, and an <a href="https://www.dynair.hu/termek/dynair-fcp-atex-fcp-v-atex-single-speed-centrifugal-roof-fans/" target="_blank" rel="noopener">ATEX certified version</a> for potentially flammable or explosive environments (See: <a href="https://www.dynair.hu/term%C3%A9kkateg%C3%B3ria/atex-fans/" target="_blank" rel="noopener">ATEX Fans</a>).</p>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fcp-single-speed-centrifugal-roof-fans-with-horizontal-discharge/">Dynair FCP single-speed centrifugal roof fans with horizontal discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Portable centrifugal fan powered by a Honda engine</title>
		<link>https://www.dynair.hu/termek/portable-centrifugal-fan-powered-by-a-honda-engine/</link>
		
		<dc:creator><![CDATA[Bruscagnin Bruno]]></dc:creator>
		<pubDate>Wed, 29 Dec 2021 10:50:13 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=12239</guid>

					<description><![CDATA[<p>KOMPEL Kft. offers a wide variety of high performance, efficient, and easily portable fans and other ventilation devices. Closed space ventilation, and ventilation of areas with toxic, flammable gases require complete compliance with safety guidelines, prescribed by the pertaining authorities. Such environments include tunnels, basements, manholes, silos, petrochemical plants, wells, fuel stations, warehouses, mines, laboratories, confined space excavations, gas distribution networks and many other places.  The unique system to fit the hoses onto the devices allows quick setup, by simply buttoning up the hose to the pins on the device by hand. The polyetylene volute and impeller can be washed by hand, and reqiure minimal maintenance. The whole machine is very robust, thanks to the polyetylene and stainless steel construction, which are resistant to impacts, rust and even the majority od acidic chemical agents.</p>
<p><a href="https://www.dynair.hu/wp-content/uploads/2022/01/Depliant-HO-727.pdf" target="_blank" rel="noopener"><span style="font-size: 18pt;"><strong>CATALOGUE</strong></span></a></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/portable-centrifugal-fan-powered-by-a-honda-engine/">Portable centrifugal fan powered by a Honda engine</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Safety notes regarding the use of aspirators:</strong></p>
<p>For maximum safety, never use any ventilator if the nature of the fumes is unknown, or the gases to be extracted could be flammable, or even explosive. In these cases, only positive ventilation can be used, blowing into the contaminated area, creating an „air wash” without sucking any gases up with the device.</p>
<p>Extraction and then  pressurization of explosive gases can make them even more explosive and reactive to any spark or flame.</p>
<p>The hydraulic, single-phase, or electric single-phase models can only extract toxic or poisonous but not explosive fumes, such as exhaust gases, welding fumes, CO2, etc.</p>
<p>There have been many cases where in attempt to help a victim, stunned by gas, the rescuers didn’t realise the cause of the accident, and they too were fatally poisoned.</p>
<p>Some toxic gases, and even the lack of oxygen are odourless, and can be fatal without any sign of danger.</p>
<p><strong>Construction and specifications:</strong></p>
<ul>
<li>HO727 version powered by a Honda GX120 3 hp (2,2 kW) pull start engine <span style="font-size: 12pt;">(<a class="g-color-black" style="font-weight: bold; background-color: #ffffff;" href="https://engines.honda.com/models/model-detail/mid-gx#!" rel="nofollow noopener" target="_blank">ENGINE DETAILS</a>)</span></li>
<li>The whole device weighs 24 kg</li>
<li>Airflow: up to 2100m<sup>3</sup>/h</li>
<li>Outlet diameter: 20 cm</li>
<li>Frame made from stainles steel, featuring a carrying handle</li>
<li>Volute casing made out of polyethylene</li>
<li>Dimensions: 600 x 570 x 740 mm</li>
</ul>
<p>Available in electric (HE828) and hydraulic (PE18H) versions as well.</p>
<p class="h5 d-inline-block text-uppercase g-mr-10"><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>&nbsp;</p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/portable-centrifugal-fan-powered-by-a-honda-engine/">Portable centrifugal fan powered by a Honda engine</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair SS-BOX Super-silent acoustic cabinet fans</title>
		<link>https://www.dynair.hu/termek/dynair-ss-box-super-silent-acoustic-cabinet-fans/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Thu, 02 Aug 2018 12:12:16 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=8752</guid>

					<description><![CDATA[<p>The extremely low noise level makes these super-silenced boxed fans an exclusive and unmatched product. SS-BOX fans are suitable for applications in small exhausting plants with limited space, where easy installation is also required. Other peculiar features are: the possibility of easy removal of motor-impeller assembly for maintenance purposes, the standardized round inlet and outlet flanges and the possibility of speed regulation. They are suitable for conveying clean air with temperatures ranging  from -10°C to +40°C. They must only be installed in horizontal position.</p>
<p>&#160;</p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/SS-BOX-construction.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-ss-box-super-silent-acoustic-cabinet-fans/">Dynair SS-BOX Super-silent acoustic cabinet fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Main structure made from galvanized steel sheet.</li>
<li>Inside lined with 50mm thick acoustic insulation.</li>
<li>Single-phase electric motor, with IP44 or IP20 grade ingress protection, class F insulation and automatic thermal protection. Suitable for speed regulation.</li>
<li>Backward-curved impeller blades on the 125-250 mm models.</li>
<li>Double inlet forward-curved impeller blades on the 315-450 mm models.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Shutters</li>
<li>Protection guards</li>
<li>Collars for connecting to the duct</li>
<li>Silencers</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-ss-box-super-silent-acoustic-cabinet-fans/">Dynair SS-BOX Super-silent acoustic cabinet fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair ZOO belt-driven axial fans</title>
		<link>https://www.dynair.hu/termek/dynair-zoo-belt-driven-axial-fans/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Fri, 27 Jul 2018 11:21:28 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=8737</guid>

					<description><![CDATA[<p>These fans were specifically designed to be used in highly corrosive and/or very humid environemnts. Common applications include greenhouses, farms, agricultural estabilishmentes, car washes, creameries,  or compressor enclosures. These devices can be easily mounted onto a wall, and can operate in temperatures between -20°C and +60°C. The ZOO range consists of  two different models; the ZOO R and the ZOO S. While the ZOO R features a protective wire grill on both sides, the ZOO S only has one on the inlet side, and is instead equipped with a gravity shutter on the outlet side. Both versions are available in 5 different sizes, with impeller sizes between 660 and 1270 mm in diameter.</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/ZOO.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-zoo-belt-driven-axial-fans/">Dynair ZOO belt-driven axial fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Belt-driven fans.</li>
<li>Motor outside the path of airflow.</li>
<li>Housing made from galvanized steel sheet.</li>
<li>Impeller blades made out of AISI 304 stainless steel, with an aluminium hub.</li>
<li>Asynchronous three phase, ball bearing motor, suitable for continuous operation at 230/400V~50Hz.</li>
<li>Protection grade: IP54.</li>
<li>Insulation: Class F.</li>
</ul>
<p>Single phase motor version available upon request.</p>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-zoo-belt-driven-axial-fans/">Dynair ZOO belt-driven axial fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair CCZ Compact and high efficiency ducted axial fans</title>
		<link>https://www.dynair.hu/termek/dynair-ccz-compact-and-high-efficiency-ducted-axial-fans/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Fri, 27 Jul 2018 10:14:24 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=8733</guid>

					<description><![CDATA[<p>The duct axial fans of the CCZ series are used for ducted installations requiring large airflow with relatively low pressure drop, like ventilation and cooling systems in industrial, naval, commercial, civil and energetic fields. These fans are particularly easy to install and maintain thanks to their compact size, and lack of protruding parts. The motors are continuously speed controllable and ensure low noise operation. The CCZ series consists of 6 different sized models, with impeller diamters ranging from 310 to 560 mm. These fans are suitable for conveying clean air in temperatures between -25°C and +60°C.</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<h3><a href="https://www.dynair.hu/wp-content/uploads/2021/05/CCZ.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="https://www.dynair.hu/wp-content/uploads/2021/07/accessori.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-ccz-compact-and-high-efficiency-ducted-axial-fans/">Dynair CCZ Compact and high efficiency ducted axial fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Short casing made out of steel sheet, with fixing flanges manufactured according to the UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint.</li>
<li>High quality aerofoil profile impellers made from technopolymer reinforced with mineral fibers (models 310 to 400) or die cast aluminum alloy (models 450 to 560). Blades are attached directly to the external rotor of the motor, with airflow from motor to impeller.</li>
<li>External rotor motors with built-in thermal protection, available in a single-phase variable speed, or three-phase double-speed version. Connection box on the casing (up to model 400) or on the motor (models 450 to 560).</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Flat protection guard (CCr)</li>
<li>Flexible connectors (CCga)</li>
<li>Inlet/outlet bell mouth (CCbo)</li>
<li>Silencers, with or without pod, available in three lengths (CCsa and CCsb)</li>
<li>Flat counter flange (Ccf)</li>
<li>Counter flange with collar (CCfc)</li>
<li>Anti-vibration mounts</li>
</ul>
<p><strong>Available upon request:</strong></p>
<ul>
<li>Casing protected against atmospheric agents by hot-dip galvanizing</li>
<li>Portable version, with a stand (<a href="https://www.dynair.hu/termek/dynair-ccp-portable-duct-axial-fans/" target="_blank" rel="noopener">CCP</a>)</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-ccz-compact-and-high-efficiency-ducted-axial-fans/">Dynair CCZ Compact and high efficiency ducted axial fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair TA-HP high performance ducted axial fan</title>
		<link>https://www.dynair.hu/termek/dynair-ta-hp-high-performance-ducted-axial-fan/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Fri, 27 Jul 2018 09:31:35 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=8728</guid>

					<description><![CDATA[<p>TA-HP fans are particularly long-lasting, robust, and provide outstanding performance, thanks to the aerofoil profile blades, along with the aerodynamically optimized design. The long casing construction allows for easy installation. They are available in a wide variety of configurations; offering fans with 6, 9, or 12 blades, measuring between 400 and 1600mm in diameter, available with 2,4,6 or even 8 pole motors. This series of fans are suitable for running in temperatures between -20°C and +70°C. The ErP conformity is defined in phase of selection via Blowdyn 2.0 software or by contacting Kompel Kft directly.</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<p><a href="https://www.dynair.hu/wp-content/uploads/2018/07/TA-DYNAIR-hosszuhazas-karimas-axial-ventilator.pdf"><img class="alignnone size-full wp-image-12475" src="https://www.dynair.hu/wp-content/uploads/2018/07/TA-HP_info.jpg" alt="" width="200" height="278" /></a></p>
<h3><a href="https://www.dynair.hu/wp-content/uploads/2021/07/TA-HP.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/CC-HP-ACCESSORIES.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-ta-hp-high-performance-ducted-axial-fan/">Dynair TA-HP high performance ducted axial fan</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Long casing made from steel sheet, painted in epoxy, equipped with fixing flanges, manufactured in compliance with the UNI ISO 6580-EUROVENT standard.</li>
<li>High performance axial impeller with aerofoil blades, made completely out of die-cast aluminium. Balanced according to ISO 1940 standard. The pitch angle of the blades can be adjusted when stationary.</li>
<li>Inspection door.</li>
<li>Asynchronous three-phase IE2 motors,CE marked, with IP55 protection and Class F insulation, compliant with the following international standards: IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE.</li>
<li>Impeller coupled directly to the motor.</li>
<li>Suitable for S1 service(continuous operation at constant load).</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Inlet/outlet cone (CCbo)</li>
<li>Flexible joint (CCga)</li>
<li>Flat protection grid (CCr)</li>
<li>Support feet (CCst)</li>
<li>Counter flange (CCf)</li>
<li>Counter flange with collar (CCfc)</li>
<li>Cylindrical silencers with or without pod (CCsa/CCsb)</li>
<li>Roof exit kit (<a href="https://www.dynair.hu/termek/dynair-tav-vertical-discharge-axial-conveyors/" target="_blank" rel="noopener">TAV adapter</a>)</li>
</ul>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-ta-hp-high-performance-ducted-axial-fan/">Dynair TA-HP high performance ducted axial fan</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair FCV 2V dual-speed centrifugal roof fans with vertical discharge</title>
		<link>https://www.dynair.hu/termek/dynair-fcv-2v-dual-speed-centrifugal-roof-fans-with-vertical-discharge/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Fri, 27 Jul 2018 06:47:57 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=8714</guid>

					<description><![CDATA[<p>This series of fans features a unique, three-phase motor, with the ability to switch between star and delta configurations, in order to provide two different operating speeds. The motor is outside the path of airflow, allowing  efficient extraction of clean or even slightly dusty air, with temperatures up to 100°C. These fans are suitable for direct or ducted extraction, in residential, commercial, or even industrial applications. Their ingenious design allows for easy installation and smooth, efficient, low noise operation. The <a href="https://www.dynair.hu/termek/dynair-fc-2v-dual-speed-centrifugal-roof-fans-with-horinzontal-discharge/" target="_blank" rel="noopener">FC-2V</a> version features horizontal, the FCV-2V vertical discharge. Available in multiple different sizes; from 650 to 1400mm in diameter.</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC2V-FCV2V-CONSTRUCTION.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC2V-FCV2V-ACCESSORIES.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fcv-2v-dual-speed-centrifugal-roof-fans-with-vertical-discharge/">Dynair FCV 2V dual-speed centrifugal roof fans with vertical discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel.</li>
<li>Protective shroud manufactured from drawn steel rods, compliant with UNI 10615:1997 regulations.</li>
<li>Backward curved blade impeller made from galvanized steel, designed for high efficiency and low noise operation, balanced statically and dynamically according to the ISO 1940 standard.</li>
<li>Asynchronous, double polarity three-phase motor, CE marked,equipped with IP55 grade protection, Class F insulation, compliant with the following standards: IEC 60034, Iec 60072, EMC 2014/30/UE, LVD 2014/35/UE.</li>
<li>Upper cover made from ABS plastic, featuring cooling slots for the motor.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Backdraught gravity shutters (TS)</li>
<li>Silencer(GR)</li>
<li>Mounting plate for corrugated roofs (BA)</li>
<li>Inlet protection guard(RA)</li>
<li>Service switch</li>
<li>Silenced mounting plate (PB)</li>
</ul>
<p><strong>Special versions:</strong></p>
<ul>
<li><a href="https://www.dynair.hu/termek/dynair-fc-at-fc-2v-at-single-or-dpouble-speed-centrifugal-roof-fans-for-air-temperature-up-to-200c/" target="_blank" rel="noopener">AT version</a>:<em> horizontal discharge</em> version, made for constant operation in environmnents with air temperatures up to 200°C).
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/high-temperature-fans-200c/" target="_blank" rel="noopener">High temperature fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-fc-ht-centrifugal-roof-fans-f400/" target="_blank" rel="noopener">HT version</a>: <em>horizontal discharge, single-speed </em>version made for heat and smoke extraction (F400).
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/smoke-and-heat-extract-fans-and-fire-fighting-systems/smoke-extract-fans/" target="_blank" rel="noopener">Smoke extraction fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-fc-fcv-atex-single-speed-centrifugal-roof-fans/" target="_blank" rel="noopener">ATEX version</a>: ATEX certified, <em>single-speed</em> version, compliant with directives 94/9/CE and 2014/34/UE.
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/atex-fans/" target="_blank" rel="noopener">ATEX Fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fcv-2v-dual-speed-centrifugal-roof-fans-with-vertical-discharge/">Dynair FCV 2V dual-speed centrifugal roof fans with vertical discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair FC 2V dual-speed centrifugal roof fans with horinzontal discharge</title>
		<link>https://www.dynair.hu/termek/dynair-fc-2v-dual-speed-centrifugal-roof-fans-with-horinzontal-discharge/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Fri, 27 Jul 2018 06:37:21 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=8712</guid>

					<description><![CDATA[<p>This series of fans features a unique, three-phase motor, with the ability to switch between star and delta configurations, in order to provide two different operating speeds. The motor is outside the path of airflow, allowing  efficient extraction of clean or even slightly dusty air, with temperatures up to 100°C. These fans are suitable for direct or ducted extraction, in residential, commercial, or even industrial applications. Their ingenious design allows for easy installation and smooth, efficient, low noise operation. The FC-2V version features horizontal, the <a href="https://www.dynair.hu/termek/dynair-fcv-2v-double-speed-centrifugal-roof-fans-vertical-discharge/" target="_blank" rel="noopener">FCV-2V</a> vertical discharge. Available in multiple different sizes; from 600 to 1100mm in diameter.</p>
<p>This product complies with the European Union's ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC2V-FCV2V-CONSTRUCTION.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC2V-FCV2V-ACCESSORIES.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fc-2v-dual-speed-centrifugal-roof-fans-with-horinzontal-discharge/">Dynair FC 2V dual-speed centrifugal roof fans with horinzontal discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel.</li>
<li>Protective shroud manufactured from drawn steel rods, compliant with UNI 10615:1997 regulations.</li>
<li>Backward curved blade impeller made from galvanized steel, designed for high efficiency and low noise operation, balanced statically and dynamically according to the ISO 1940 standard.</li>
<li>Asynchronous, double polarity three-phase motor, CE marked,equipped with IP55 grade protection, Class F insulation, compliant with the following standards: IEC 60034, Iec 60072, EMC 2014/30/UE, LVD 2014/35/UE.</li>
<li>Upper cover made from ABS plastic, featuring cooling slots for the motor.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Backdraught gravity shutters (TS)</li>
<li>Silencer(GR)</li>
<li>Mounting plate for corrugated roofs (BA)</li>
<li>Inlet protection guard(RA)</li>
<li>Service switch</li>
<li>Silenced mounting plate (PB)</li>
</ul>
<p><strong>Special versions:</strong></p>
<ul>
<li><a href="https://www.dynair.hu/termek/dynair-fc-at-fc-2v-at-single-or-dpouble-speed-centrifugal-roof-fans-for-air-temperature-up-to-200c/" target="_blank" rel="noopener">AT version</a>: made for constant operation in environmnents with air temperatures up to 200°C)
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/high-temperature-fans-200c/" target="_blank" rel="noopener">High temperature fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-fc-ht-centrifugal-roof-fans-f400/" target="_blank" rel="noopener">HT version</a>: <em>single-speed</em> version made for heat and smoke extraction (F400)
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/smoke-and-heat-extract-fans-and-fire-fighting-systems/smoke-extract-fans/" target="_blank" rel="noopener">Smoke extraction fans</a>)</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-fc-fcv-atex-single-speed-centrifugal-roof-fans/" target="_blank" rel="noopener">ATEX version</a>: ATEX certified, <em>single-speed</em> version, compliant with directives 94/9/CE and 2014/34/UE
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/atex-fans/" target="_blank" rel="noopener">ATEX Fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener"><span style="font-size: 18.6667px;">For further details, feel free to contact KOMPEL Kft.</span></a></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fc-2v-dual-speed-centrifugal-roof-fans-with-horinzontal-discharge/">Dynair FC 2V dual-speed centrifugal roof fans with horinzontal discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair DA-T Direct drive double inlet fans without motor</title>
		<link>https://www.dynair.hu/termek/dynair-da-direct-drive-double-inlet-fans-without-motor/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Thu, 26 Jul 2018 10:14:55 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=8705</guid>

					<description><![CDATA[<p>The DA-T series of fans are designed to be used in ventilation, air conditioning, filtering, or heating plants. These fans can handle clean air between -20°C and +80°C. They require a casing to be fitted in (plenum), to work properly. The fans must be used according to the specified limits shown in the catalogue. Available in 11 different sizes, with no motor included.</p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/DA-T-CONSTRUCTION.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/DA-T-ACCESSORIES.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-da-direct-drive-double-inlet-fans-without-motor/">Dynair DA-T Direct drive double inlet fans without motor</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Galvanized steel volute</li>
<li>Double inlet , forward curved impeller, with a steel shaft supported by ball bearings</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Outlet flange</li>
<li>Mounting brackets</li>
<li>Motor support for execution 14/D</li>
</ul>
<p><strong>Available upon request:</strong></p>
<ul>
<li>„CUBIK” version with independent frame included</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-da-direct-drive-double-inlet-fans-without-motor/">Dynair DA-T Direct drive double inlet fans without motor</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>