<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Fire Fighting Lobbies &#8211; Dynair.hu</title>
	<atom:link href="https://www.dynair.hu/term%C3%A9kkateg%C3%B3ria/smoke-and-heat-extract-fans-and-fire-fighting-systems/fire-fighting-lobbies/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.dynair.hu</link>
	<description>Dynair ventilation</description>
	<lastBuildDate>Thu, 25 Aug 2022 11:32:28 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.dynair.hu/wp-content/uploads/2022/01/favicon.jpg</url>
	<title>Fire Fighting Lobbies &#8211; Dynair.hu</title>
	<link>https://www.dynair.hu</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Dynair REIDUCT-C Aeraulic circular ducting systems</title>
		<link>https://www.dynair.hu/termek/dynair-reiduct-c-aeraulic-circular-ducting-systems/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 07 Aug 2018 06:59:27 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=8796</guid>

					<description><![CDATA[<p>The REIDUCT-C series are a circular cross-section airvent systems, featuring a double-walled metal duct sections made from embossed aluminium. They are certified for fire resistance according to the UNI-EN 1366-1:2014 standard, and feature EI120 class fire protection, according to the UNI EN 13501-3 + A1 2009 standard. The series features ducts, curves and many different adapters, all suitable for horizontal or vertical installation. The internal wall features a conical joint made from AISI316L stainless steel. These products feature great smoke tightness, with a loss of less than 10 m<sup>3</sup>/m<sup>2</sup>. Air tightness of these ducts is Class C (2,000 Pa), as defined by the UNI EN 1507: 2008 standard.</p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/REIDUCT-C.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-reiduct-c-aeraulic-circular-ducting-systems/">Dynair REIDUCT-C Aeraulic circular ducting systems</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Available sizes:</strong></p>
<ul>
<li>Inner diameter: 200/250/300 mm</li>
<li>Useful length: 194/444/944 mm</li>
<li>Standard length: 1340 mm</li>
</ul>
<p>These ducts are compatible with the SVP fire-extinguishing systems.</p>
<p>Also available with a rectangular cross-section: <a href="https://www.dynair.hu/termek/dynair-reiduct-q-aeraulic-square-ducting-ei120/" target="_blank" rel="noopener">REIDUCT-Q</a>.</p>
<p>For the complete product range, see the catalogue.</p>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-reiduct-c-aeraulic-circular-ducting-systems/">Dynair REIDUCT-C Aeraulic circular ducting systems</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair REIDUCT-Q Aeraulic square ducting system</title>
		<link>https://www.dynair.hu/termek/dynair-reiduct-q-aeraulic-square-ducting-system/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 07 Aug 2018 06:33:26 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=8793</guid>

					<description><![CDATA[<p>The REIDUCT-Q series are rectangular cross-section airvent systems, featuring double-walled metal duct sections made from embossed aluminium. They are certified for fire resistance according to the UNI-EN 1366-1:2014 standard, and feature EI120 class fire protection, according to the UNI EN 13501-3 + A1 2009 standard. The series features ducts, curves and many different adapters, all suitable for horizontal or vertical installation. These products feature great smoke tightness, with a loss of less than 10 m<sup>3</sup>/m<sup>2</sup>. Air tightness of these ducts is Class C (2,000 Pa), as defined by the UNI EN 1507: 2008 standard.</p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/REIDUCT-Q.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-reiduct-q-aeraulic-square-ducting-system/">Dynair REIDUCT-Q Aeraulic square ducting system</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Available sizes:</strong></p>
<ul>
<li>Base: 200 + 1.250 mm</li>
<li>Height: 200 + 1.000 mm</li>
<li>Pitch: 50 mm</li>
<li>Length: 1.340 mm</li>
<li>Duct thickness: 50 mm</li>
</ul>
<p>These ducts are compatible with the SVP fire-extinguishing systems.</p>
<p>Also available with a circular cross-section: <a href="https://www.dynair.hu/termek/dynair-reiduct-c-aeraulic-circular-ducting-ei120/" target="_blank" rel="noopener">REIDUCT-C</a>.</p>
<p>For the complete product range, see the catalogue.</p>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-reiduct-q-aeraulic-square-ducting-system/">Dynair REIDUCT-Q Aeraulic square ducting system</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair SVP Fire fighting lobbies</title>
		<link>https://www.dynair.hu/termek/dynair-svp-fire-fighting-lobbies/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 07 Aug 2018 06:16:46 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=8790</guid>

					<description><![CDATA[<p>The SVP series are Pressurizing units for fire-fighting lobbies, available in multiple different setups. The unit consists of a control panel, a pressurization unit with DC or EC motors, auxiliary batteries, and remote sensors, depending on the chosen model. The pressurization system can be activated in emergency conditions either autonomously by the sensors, or manually from a fire protection control unit, via remote access.</p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/SVP.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-svp-fire-fighting-lobbies/">Dynair SVP Fire fighting lobbies</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h1><span style="font-size: 12pt;"><strong>Operation:</strong></span></h1>
<p>The pressurization system can be activated in emergency situations, either independently (by having the system connected to conventional smoke or heat detectors) or from an external signal coming from a fire protection control unit (via remote input).<br />
The REI fire protection doors of the fire lobby are automatically closed by electronically releasing the locks. At the same time, the pressirizer puts the room under over pressure, reaching the minimum threshold of 30 Pa.<br />
Once this pressure value is reached, the unit modulates its operation, to keep the pressure above 30 Pa.<br />
The system works for a minimum of 120 minutes, even in the event of a blackout, thanks to the included batteries. When a door is opened, the system reduces its overpressure, allowing the door to close correctly. After a maximum of 2 seconds, the pressure inside the firefighting room returns to at least 30 Pa.</p>
<h1><span style="font-size: 12pt;"><strong>Installation:</strong></span></h1>
<p>Correct installation of an SVP unit requires a dedicated power line with an adequately sized magnetic circuit breaker, that fits the local laws and standards. An air duct system is also required, with EI120 certification, possibly from the REIDUCT series, with the least possible number of bends or restrictions. The pressurization unit must be placed on the wall, right below the ceiling, so people are not directly in the path of the airflow. The control panel must be placed at an accessible height in compliance with the latest laws and electrical standards, and can not be placed in areas with automatic extinguishing systems, ora areas exposed to weather. SVP systems must not be installed in rooms with potential fire load.</p>
<h1><span style="font-size: 12pt;"><strong>Available versions:</strong></span></h1>
<p>All SVP units require 230V~50Hz.</p>
<ul>
<li>
<h2><span style="font-size: 12pt;"><strong>SVP1:</strong></span></h2>
<ul>
<li>Max current: 2 A</li>
<li>Max flow rate: 2700 m<sup>3</sup>/h</li>
<li>Max overpressure: 270 Pa</li>
<li>Designed for emeregeny use only</li>
</ul>
</li>
<li>
<h2><span style="font-size: 12pt;"><strong>SVP2:</strong></span></h2>
<ul>
<li>Max current: 2.65 A</li>
<li>Max flow rate: 2200 m<sup>3</sup>/h</li>
<li>Max overpressure: 300 Pa</li>
<li>EC brushless motor</li>
<li>Suitable for 24h operation</li>
</ul>
</li>
<li>
<h2><span style="font-size: 12pt;"><strong>SVP2+:</strong></span></h2>
<ul>
<li>Max current: 1.7 A</li>
<li>Max flow rate: 3300 m<sup>3</sup>/h</li>
<li>Max overpressure: 400 Pa</li>
<li>EC brushless motor</li>
<li>Suitable for 24h operation</li>
</ul>
</li>
<li>
<h2><span style="font-size: 12pt;"><strong>SVP4:</strong></span></h2>
<ul>
<li>Max current: 3.9 A</li>
<li>Max flow rate: 4400 m<sup>3</sup>/h</li>
<li>Max overpressure: 650 Pa</li>
<li>EC brushless motor</li>
<li>Suitable for 24h operation</li>
</ul>
</li>
<li>
<h2><span style="font-size: 12pt;"><strong>SVP5:</strong></span></h2>
<ul>
<li>Max current: 3.9 A</li>
<li>Max flow rate: 6500 m<sup>3</sup>/h</li>
<li>Max overpressure: 400 Pa</li>
<li>EC brushless motor</li>
<li>Suitable for 24h operation</li>
</ul>
</li>
</ul>
<p>For a wide variety of accessories, see the catalogue.</p>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/hu/kapcsolat/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>&nbsp;</p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-svp-fire-fighting-lobbies/">Dynair SVP Fire fighting lobbies</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>