<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Smoke Extract Fans &#8211; Dynair.hu</title>
	<atom:link href="https://www.dynair.hu/term%C3%A9kkateg%C3%B3ria/smoke-and-heat-extract-fans-and-fire-fighting-systems/smoke-extract-fans/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.dynair.hu</link>
	<description>Dynair ventilation</description>
	<lastBuildDate>Mon, 22 Aug 2022 08:07:42 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.dynair.hu/wp-content/uploads/2022/01/favicon.jpg</url>
	<title>Smoke Extract Fans &#8211; Dynair.hu</title>
	<link>https://www.dynair.hu</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Dynair TA-HT High performance duct axial fans F300/120 &#8211; F400</title>
		<link>https://www.dynair.hu/termek/dynair-ta-ht-high-performance-duct-axial-fans-f300-120-f400-2/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Mon, 02 Mar 2020 11:03:41 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=10138</guid>

					<description><![CDATA[<p>The TA-HT fans are designed for applications requiring an absolute conformity to high specifications in terms of pressure and air volume. The TA-HT series are particularly robust and long-lasting, with high performance, thanks to their aerdoynamically optimized aerofoil blades. The long casing allows for easy installation. These fans are available with 2,4,6, or even 8 pole motors, and 6,9, or 12 blade impellers. They are suitable for extraction of clean air between -20°C and +70°C in continuous operation, and are F300/120 and F400 certified by the independent APPLUS committee, according to the EN 12101-3 standard. The ErP conformity can be selected via the aid of the Blowdyn 2.0 software, or by contacting KOMPEL Kft. directly.</p>
<p>Az ErP szabályoknak megfelelő modell kiválasztásában a Blowdyn 2.0 szoftver segít, vagy keresse fel nyugodtan a KOMPEL Kft-t.</p>
<p>Diameter: 400 – 1 600 mm<br />
Airflow: up to 165 000 m<sup>3</sup>/h<br />
Max static pressure rise: 2 200 Pa<br />
Max temperature in continuous operation: 70 °C.</p>
<p>Available with the following certifications:</p>
<p>F400 (+400°C for up to 2 hours),</p>
<p>F300 (+300°C for up to an hour),</p>
<p>F200 (+200°C for up to 2 hours),</p>
<p>F300/120 (+300°C for up to 2 hours).</p>
<p><a href="https://www.dynair.hu/wp-content/uploads/2018/07/TA-DYNAIR-hosszuhazas-karimas-axial-ventilator.pdf"><img class="alignnone size-full wp-image-12475" src="https://www.dynair.hu/wp-content/uploads/2018/07/TA-HP_info.jpg" alt="" width="200" height="278" /></a></p>
<h3><a href="https://www.dynair.hu/wp-content/uploads/2021/07/TA-HT-Dynair.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-ta-ht-high-performance-duct-axial-fans-f300-120-f400-2/">Dynair TA-HT High performance duct axial fans F300/120 &#8211; F400</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Long casing made from steel sheet, painted in epoxy, equipped with fixing flanges, manufactured in compliance with the UNI ISO 6580-EUROVENT standard.</li>
<li>High performance axial impeller with aerofoil blades, made completely out of die-cast aluminium. Balanced according to ISO 1940 standard. The pitch angle of the blades can be adjusted when stationary.</li>
<li>Inspection door.</li>
<li>Asynchronous three-phase IE2 motors,CE marked, with IP55 protection and Class H insulation, compliant with the following international standards: IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE.</li>
<li>Impeller coupled directly to the motor.</li>
<li>Suitable for S1 service(continuous operation at constant load).</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Inlet/outlet cone (CCbo)</li>
<li>Damper (CCda)</li>
<li>Outlet terminal (CCot)</li>
<li>High temp flexible joint (CCga-HT)</li>
<li>Flat protection grid (CCr)</li>
<li>Support feet (CCst)</li>
<li>Counter flange (CCf)</li>
<li>Counter flange with collar (CCfc)</li>
<li>Cylindrical silencers with or without pod (CCsa/CCsb)</li>
<li>Anti-vibration mounts</li>
</ul>
<p><strong>Available upon request:</strong></p>
<ul>
<li>Casing protected against atmospheric agents by hot dip galvanizing</li>
<li>High temperature external terminal box</li>
<li>IE3 motor</li>
<li>2 speed version</li>
<li>Reversible models</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-ta-ht-high-performance-duct-axial-fans-f300-120-f400-2/">Dynair TA-HT High performance duct axial fans F300/120 &#8211; F400</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair BOX-T HT Belt driven double inlet box fans F400</title>
		<link>https://www.dynair.hu/termek/dynair-box-t-ht-belt-driven-double-inlet-box-fans-f400/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Mon, 06 Aug 2018 13:35:31 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=8788</guid>

					<description><![CDATA[<p>The belt-driven double inlet BOX-T HT fans are designed to be used in industrial plants, which require fire smoke to be exhausted out. These fans are suitable for conveying clean air and non-dusty smoke up to 200°C in continuous operation, and up to 400°C for a period of 2 hours in case of an emergency. This series of fans are F400 certified by the independent APPLUS committee, according to EN12101-3 standards.</p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/BOX-T-HT.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-box-t-ht-belt-driven-double-inlet-box-fans-f400/">Dynair BOX-T HT Belt driven double inlet box fans F400</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Dismountable cabinet made from galvanized steel sheet. Double inlet impeller with forward curved blades made out of galvanized steel sheet.</li>
<li>Belt coupling with self-aligning supports, outside the path of airflow. Height adjustable motor support plate for the tensioning of the belt. Belt coupling protected by a galvanized steel guard.</li>
<li>Asynchronous three-phase motor, with IP55 grade protection and class F insulation, available in single- or double polarity versions in B3 standard mounting type. Suitable for continuos &#8220;S1&#8221; service at constant load.</li>
<li>Arrangement 9: belt coupling with motor placed on the upper panel.</li>
<li>Arrangement 12: belt coupling with motor placed aside on a common basement (only for motors above 7.5 kW)</li>
</ul>
<p><strong>Available upon request:</strong></p>
<ul>
<li>Double polarity motor.</li>
</ul>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-box-t-ht-belt-driven-double-inlet-box-fans-f400/">Dynair BOX-T HT Belt driven double inlet box fans F400</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair TC-HT Centrifugal roof fans vertical discharge</title>
		<link>https://www.dynair.hu/termek/dynair-tc-ht-centrifugal-roof-fans-vertical-discharge/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:05 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8114/</guid>

					<description><![CDATA[<p>The TC-HT series of centrifgual roof fans are designed for direct or ducted smoke extraction, up to +150°C in continuous operation. The main characteristic of these fans is their vertical exhaust conveyor which guarantees optimized safety in the event of a fire: fast and effective toxic fume extraction, leading to safer escape routes, easier access for the emergency teams, and minimizing the effects of fire on the building structures. These fans are F400 certified by the independent APPLUS committee, according to EN 12101-3 standards.</p>
<p>Airflow: up to 20 000 m<sup>3</sup>/h<br />
Max static pressure rise: 820 Pa<br />
Max temperature in continuous operation: 150°C</p>
<p>Absolute max temperature: 400°C/2 hours (F400)</p>
<h3><a href="https://www.dynair.hu/wp-content/uploads/2021/05/TC-HT.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-tc-ht-centrifugal-roof-fans-vertical-discharge/">Dynair TC-HT Centrifugal roof fans vertical discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel, with an epoxy finish.</li>
<li>Protective shroud manufactured from drawn steel rods, protected against atmospheric agents.</li>
<li>High efficiency, low noise, backward curved blade impeller made from galvanized steel sheet, statically and dynamically balanced statically and dynamically according to ISO 1940 standards. The impeller can withstand extremely high temperatures, and ensures the proper cooling of the motor at all times.</li>
<li>Asynchronous single- or three-phase motor, CE marked, with IP55 protection and Class F insulation,  manufactured according to the following international standards: IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE. Suitable for S1 Service (continuous operation at constant load).</li>
<li>Upper cover and vertical exhaust conveyor made from galvanized steel sheet, protected against atmospheric agents with epoxy finish, in grey RAL 7001.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Counter base to be walled up (CB)</li>
<li>Inlet protection guard (RA)</li>
</ul>
<p><strong>Available upon request:</strong></p>
<ul>
<li>Service switch for high temperatures</li>
<li>Terminal box for high temperatures</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-tc-ht-centrifugal-roof-fans-vertical-discharge/">Dynair TC-HT Centrifugal roof fans vertical discharge</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair FC-HT Centrifugal roof fans F400</title>
		<link>https://www.dynair.hu/termek/dynair-fc-ht-centrifugal-roof-fans-f400/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:05 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8115/</guid>

					<description><![CDATA[<p>The FC-HT series of centrifual roof fans are the special versions of the <a href="https://www.dynair.hu/termek/dynair-fc-single-speed-centrifugal-roof-fans-with-horizontal-discharge/" target="_blank" rel="noopener">FC series of fans</a>, designed for smoke extraction. They are suitable for both direct or ducted extraction of smoke, with tempeatures up to +80°C in continuous operation, and are F400 certified by the APPLUS committee.</p>
<p>Airflow: up to 17 000 m<sup>3</sup>/h<br />
Max static pressure rise: 750 Pa<br />
Max temperature in continuous operation: 80 °C<br />
Certification: F400 (400°C for up to 2 hours)</p>
<p><a href="https://www.dynair.hu/termek/dynair-fc-single-speed-centrifugal-roof-fans-with-horizontal-discharge/" target="_blank" rel="noopener">Details of the FC series</a></p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/FC-HT-catalogue.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fc-ht-centrifugal-roof-fans-f400/">Dynair FC-HT Centrifugal roof fans F400</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Mounting plate made from galvanized steel.</li>
<li>Protective shroud manufactured from drawn steel rods, compliant with UNI 10615:1997 regulations.</li>
<li>High efficiency, low noise, backward curved blade impeller made from galvanized steel sheet, statically and dynamically balanced statically and dynamically according to ISO 1940 standards.</li>
<li>Asynchronous  three-phase dual-speed motor, CE marked, with IP55 protection and Class F insulation,  manufactured according to the following international standards: IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE. Suitable for S1 Service (continuous operation at constant load).</li>
<li>Power supply: 400V~50Hz three phase.</li>
<li>Upper cover made from ABS plastic, featuring cooling slots for the motor.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Counter base to be walled up (CB)</li>
<li>Inlet side protection guard (CCr)</li>
</ul>
<p><strong>Available upon request:</strong></p>
<ul>
<li>Service switch</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-fc-ht-centrifugal-roof-fans-f400/">Dynair FC-HT Centrifugal roof fans F400</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair PR-Q HT Backward curved centrifugal fans F400</title>
		<link>https://www.dynair.hu/termek/dynair-pr-q-ht-backward-curved-centrifugal-fans-f400/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:05 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8116/</guid>

					<description><![CDATA[<p>Backward curved blade centrifugal fans, suited for high temperature smoke extraction. The main characteristic of the PR-Q series is the rectangular construction, which allows the fan to be positioned in four different orientations (0°-90°-180°-270°) without any additional components. The lack of protruding motor support allows for a more compact design. Available in 6 sizes. These PR-Q HT fans are suitable for continuous service up to +100°C and 2 hours at temperatures up to +400°C. This series of fans are F400 certified by the independent APPLUS committee, according to EN12101-3 standards.</p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/PRQ-HT-catalogue.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-pr-q-ht-backward-curved-centrifugal-fans-f400/">Dynair PR-Q HT Backward curved centrifugal fans F400</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Volute casing with rectangular frame, made from galvanized steel sheet, coated in epoxy.</li>
<li>Single inlet, high efficiency backward-curved galvanized steel impeller with a die-cast aluminium hub.</li>
<li>Only available in Execution 5, with impeller coupled directly to the flanged motor. (Rotation:RD)</li>
<li>Asynchronous three-phase motor, with IP55 grade protection and Class F insulation, CE marked, compliant with the following standards: IEC 60034, IEC 60072, EMC 2004=108/CE, LVD 2006/95/CE. Suitable for S1 service (continuous operation at constant load).</li>
<li>Power supply: 400V~50Hz three-phase.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Inlet and outlet protection guard manufactured according to UNI 12499 standard and protected against atmospheric agents.</li>
<li>Inlet/outlet flexible connectors</li>
<li>Anti-vibration supports</li>
<li>Inlet/outlet counter flange</li>
<li>Speed controller (available in  autotransformer or inverter version)</li>
</ul>
<p><strong>Available upon request:</strong></p>
<ul>
<li>2 speed version with a double polarity motor</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-pr-q-ht-backward-curved-centrifugal-fans-f400/">Dynair PR-Q HT Backward curved centrifugal fans F400</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair CC SHT High efficiency duct axial fans F300/120 &#8211; F400</title>
		<link>https://www.dynair.hu/termek/dynair-cc-sht-high-efficiency-duct-axial-fans-f300-120-f400/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:05 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8117/</guid>

					<description><![CDATA[<div class="dati_colonna col-xs-12 col-sm-6">
<p>The CC-SHT fans are the special, high temp versions of the <a href="https://www.dynair.hu/termek/dynair-cc-ducted-axial-fan/" target="_blank" rel="noopener">CC series</a>. designed specifically for smoke extraction. Their standard dimensions allow them to easily comply with all the pertaining building safety and ventilation guidelines. These fans are suitable for conveying clean air and non-dusty smoke up to 60°C in continuous operation, and up to 300°C for a period of 2 hours in case of an emergency. This series of fans are F300/F400 certified by the independent APPLUS committee, according to EN12101-3 standards (the 2 pole versions are certified to F300/120 standard).</p>
<p>Diameter: 310 – 1 000 mm<br />
Airflow: up to 75 000 m<sup>3</sup>/h<br />
Max pressure rise: 550 Pa<br />
Max temperature in constant operation: 60 °C.</p>
<h3><a href="https://www.dynair.hu/wp-content/uploads/2021/05/CC-SHT.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
</div>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-cc-sht-high-efficiency-duct-axial-fans-f300-120-f400/">Dynair CC SHT High efficiency duct axial fans F300/120 &#8211; F400</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Short casing made out of steel sheet, with fixing flanges manufactured according to the UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint.</li>
<li>Axial impeller with aerofoil profile blades made from technopolymer with a die-cast aluminium hub, balanced according to  ISO 1940.  Pitch angle of the blades can be varied, when stationary.</li>
<li>Impeller coupled directly to motor with feet,  airflow from motor to impeller.</li>
<li>Asynchronous three-phase motors, CE marked ,with IP55 grade protection and class F or H insulation, compliant with the following international standards: IEC 60034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE. Suitable for continuous „S1” service at constant load. F200, F300, or F400 certified, according to the EN12101-3  directive.</li>
<li>Suitable for S1 service (continuous operation at constant load).</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Extension (for long casing version) with inspection porthole (CCpro)</li>
<li>Flat protection guard (CCr)</li>
<li>High heat flexible connectors (CCga-HT)</li>
<li>Support feet (CCst)</li>
<li>Inlet/outlet bell mouth (CCbo)</li>
<li>Silencers, with or without pod, available in three lengths (CCsa and CCsb)</li>
<li>Flat counter flange (Ccf)</li>
<li>Counter flange with collar (CCfc)</li>
<li>Roof terminal kit (Kit TAV-HT)</li>
<li>Anti-vibration mounts</li>
</ul>
<p><strong>Available upon request:</strong></p>
<ul>
<li>High heat external terminal box</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-cc-sht-high-efficiency-duct-axial-fans-f300-120-f400/">Dynair CC SHT High efficiency duct axial fans F300/120 &#8211; F400</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>