	<title>a Small size forward curved blade and radial centrifugal fans&#8230; &#8211; Dynair.hu</title>
	<atom:link href="https://www.dynair.hu/term%C3%A9kkateg%C3%B3ria/industrial-and-building-ventilation-fans-standard-air/small-size-forward-curved-blade-and-radial-centrifugal-fans/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.dynair.hu</link>
	<description>Dynair ventilation</description>
	<lastBuildDate>Tue, 02 Aug 2022 13:18:10 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.dynair.hu/wp-content/uploads/2022/01/favicon.jpg</url>
	<title>a Small size forward curved blade and radial centrifugal fans&#8230; &#8211; Dynair.hu</title>
	<link>https://www.dynair.hu</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Portable centrifugal fan powered by a Honda engine</title>
		<link>https://www.dynair.hu/termek/portable-centrifugal-fan-powered-by-a-honda-engine/</link>
		
		<dc:creator><![CDATA[Bruscagnin Bruno]]></dc:creator>
		<pubDate>Wed, 29 Dec 2021 10:50:13 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/?post_type=product&#038;p=12239</guid>

					<description><![CDATA[<p>KOMPEL Kft. offers a wide variety of high performance, efficient, and easily portable fans and other ventilation devices. Closed space ventilation, and ventilation of areas with toxic, flammable gases require complete compliance with safety guidelines, prescribed by the pertaining authorities. Such environments include tunnels, basements, manholes, silos, petrochemical plants, wells, fuel stations, warehouses, mines, laboratories, confined space excavations, gas distribution networks and many other places.  The unique system to fit the hoses onto the devices allows quick setup, by simply buttoning up the hose to the pins on the device by hand. The polyetylene volute and impeller can be washed by hand, and reqiure minimal maintenance. The whole machine is very robust, thanks to the polyetylene and stainless steel construction, which are resistant to impacts, rust and even the majority od acidic chemical agents.</p>
<p><a href="https://www.dynair.hu/wp-content/uploads/2022/01/Depliant-HO-727.pdf" target="_blank" rel="noopener"><span style="font-size: 18pt;"><strong>CATALOGUE</strong></span></a></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/portable-centrifugal-fan-powered-by-a-honda-engine/">Portable centrifugal fan powered by a Honda engine</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Safety notes regarding the use of aspirators:</strong></p>
<p>For maximum safety, never use any ventilator if the nature of the fumes is unknown, or the gases to be extracted could be flammable, or even explosive. In these cases, only positive ventilation can be used, blowing into the contaminated area, creating an „air wash” without sucking any gases up with the device.</p>
<p>Extraction and then  pressurization of explosive gases can make them even more explosive and reactive to any spark or flame.</p>
<p>The hydraulic, single-phase, or electric single-phase models can only extract toxic or poisonous but not explosive fumes, such as exhaust gases, welding fumes, CO2, etc.</p>
<p>There have been many cases where in attempt to help a victim, stunned by gas, the rescuers didn’t realise the cause of the accident, and they too were fatally poisoned.</p>
<p>Some toxic gases, and even the lack of oxygen are odourless, and can be fatal without any sign of danger.</p>
<p><strong>Construction and specifications:</strong></p>
<ul>
<li>HO727 version powered by a Honda GX120 3 hp (2,2 kW) pull start engine <span style="font-size: 12pt;">(<a class="g-color-black" style="font-weight: bold; background-color: #ffffff;" href="https://engines.honda.com/models/model-detail/mid-gx#!" rel="nofollow noopener" target="_blank">ENGINE DETAILS</a>)</span></li>
<li>The whole device weighs 24 kg</li>
<li>Airflow: up to 2100m<sup>3</sup>/h</li>
<li>Outlet diameter: 20 cm</li>
<li>Frame made from stainles steel, featuring a carrying handle</li>
<li>Volute casing made out of polyethylene</li>
<li>Dimensions: 600 x 570 x 740 mm</li>
</ul>
<p>Available in electric (HE828) and hydraulic (PE18H) versions as well.</p>
<p class="h5 d-inline-block text-uppercase g-mr-10"><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>&nbsp;</p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/portable-centrifugal-fan-powered-by-a-honda-engine/">Portable centrifugal fan powered by a Honda engine</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair DIC Forward curved blade centrifugal fans</title>
		<link>https://www.dynair.hu/termek/dynair-dic-forward-curved-blade-centrifugal-fans/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:14 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8165/</guid>

					<description><![CDATA[<p>The DIC series of fans are designed for industrial applications, where small air volumes and high pressures are required. Suitable for conveying clean air, or smoke up to +100°C, these fans can not handle dusty air. The series consists of 5 models, with impellers ranging from 100 to 180mm in diameter. The impeller is attached directly to the motor. Fitted with an adjustable casing, the discharge direction can be easily changed on site, in 45°intervals.</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/DIC-CATALOGUE.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/DIC-ACCESSORIES.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-dic-forward-curved-blade-centrifugal-fans/">Dynair DIC Forward curved blade centrifugal fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Volute casing made from steel sheet, protected by epoxy paint.</li>
<li>Single inlet, single width, forward curved impeller, made from galvanized steel.</li>
<li>Only available in execution 5, with the impeller attached directly to the motor.</li>
<li>Standard orientation of the fan is LG270°.</li>
<li>Single- , or three-phase asynchronous motors, with IP55 grade protection and Class F insulation, CE marked, compliant with the following international standards: IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE.</li>
<li>Models DIC 100T and M feature IP44 protection, Class B insulation, and B14 shape, while the rest of the series are B35 standard shaped.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Inlet and outlet protection guards, compliant with UNI 12499 standards, in weatherproof coating.</li>
<li>Steel motor support, covered in epoxy paint.</li>
</ul>
<p><strong>Available upon request:</strong></p>
<ul>
<li>RD rotation version.</li>
<li><a href="https://www.dynair.hu/termek/dynair-dic-atex-dic-inox-atex-forward-curved-blade-centrifugal-fans/" target="_blank" rel="noopener">DIC ATEX and DIC INOX ATEX</a> versions, compliant with ATEX directives 94/9/Ce and 2014/30/UE
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See:<a href="https://www.dynair.hu/term%C3%A9kkateg%C3%B3ria/atex-fans/" target="_blank" rel="noopener"> ATEX fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-dic-inox-centrifugal-fans-in-stainless-steel/" target="_blank" rel="noopener">DIC-INOX</a>:Corrosion resistant version, with casing, flanges, and impeller made from AISI 304 stainless steel.
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/anticorrosion-fans/" target="_blank" rel="noopener">Anticorrosion fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
<li><a href="https://www.dynair.hu/termek/dynair-dic-at-forward-curved-blade-centrifugal-fans-for-air-temperature-up-to-150c/" target="_blank" rel="noopener">DIC-AT</a>: Version suitable for conveying hot gases up to +150°C.
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/high-temperature-fans-200c/" target="_blank" rel="noopener">High temperature fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p><strong style="font-size: 16px;"> </strong></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-dic-forward-curved-blade-centrifugal-fans/">Dynair DIC Forward curved blade centrifugal fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair AL Forward curved blade centrifugal fans</title>
		<link>https://www.dynair.hu/termek/dynair-al-forward-curved-blade-centrifugal-fans/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:14 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8164/</guid>

					<description><![CDATA[<p>The AL series of centrifugal fans were primarily designed for residential and commercial applications. They can be used for ventilation with clean or slightly smoky air up to +100°C. Available in 8 different sizes, with impeller diameters ranging from 200 to 450 mm. Fitted with an adjustable casing, the discharge direction can be easily changed on site, in 45°intervals, without dismantling the whole device (except 180°and 225° which require a special construction). Standard orientation is LG 270°.</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<h3><a href="https://www.dynair.hu/wp-content/uploads/2021/05/AL.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/CC-ACCESSORIES.pdf" target="_blank" rel="noopener"><strong>ACCESSORIES</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-al-forward-curved-blade-centrifugal-fans/">Dynair AL Forward curved blade centrifugal fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Volute casing made from steel sheet, protected by epoxy paint.</li>
<li>Single inlet, single width, forward curved impeller, made from galvanized steel sheet (models 200-315) or steel sheet with blades welded on (models 355-450).</li>
<li>The impeller is coupled direcly to the motor shaft (execution 4).</li>
<li>Single- , or three-phase asynchronous motors, with IP55 grade protection and Class F insulation, CE marked, compliant with the following international standards: IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Inlet and outlet protection guard, manufactured according to UNI 12499 standard, protected against atmospheric agents.</li>
<li>Round inlet cone, made out of steel sheet, coated in epoxy.</li>
<li>Round inlet adapter.</li>
</ul>
<p><strong>Available upon request:</strong></p>
<ul>
<li><a href="https://www.dynair.hu/termek/dynair-al-atex-forward-curved-blade-centrifugal-fans/" target="_blank" rel="noopener">RD rotation ATEX version</a>, compliant with ATEX directives 94/9/CE and 2014/34/UE.
<ul>
<li style="list-style-type: none;">
<ul>
<li style="list-style-type: none;">
<ul>
<li>(See: <a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/atex-fans/" target="_blank" rel="noopener">ATEX Fans</a>)</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p><strong>Installation:</strong></p>
<ul>
<li>Centrifugal fans with forward curved blades must always be installed into ducted systems, with adeqaute resistance (e.g. setting shutters), so the airflow limits the drawn current to the value specified by the motor rating label.</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-al-forward-curved-blade-centrifugal-fans/">Dynair AL Forward curved blade centrifugal fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Dynair F aluminium centrifugal fans</title>
		<link>https://www.dynair.hu/termek/dynair-f-radial-blade-centrifugal-fans-in-aluminium/</link>
		
		<dc:creator><![CDATA[Ntamas]]></dc:creator>
		<pubDate>Tue, 19 Jun 2018 09:12:13 +0000</pubDate>
				<guid isPermaLink="false">http://www.dynair.hu/termek/import-placeholder-for-8162/</guid>

					<description><![CDATA[<p>The F series of centrifugal fans are designed to convey air in industrial applications, between -20˘C and +80°C, where small air volumes and high pressures are required. The radial impeller is fitted directly onto the motor. The die-cast aluminium impeller and volute casing provide a very low noise level, thanks to the thickness of their materials. Available in 4 different sizes.</p>
<p>Airflow: up to 1 250 m<sup>3</sup>/h<br />
Max pressure rise: 2 240 Pa<br />
Max operating temperature: 80 °C</p>
<p>This product complies with the European Union’s ecodesign directive.<br />
<a href="https://www.dynair.hu/term%c3%a9kkateg%c3%b3ria/erp-directive-compliant-fans/" target="_blank" rel="noopener">ErP Directive compliant fans</a></p>
<h3><a href="http://www.dynair.hu/wp-content/uploads/2018/08/F-CATALOGUE.pdf" target="_blank" rel="noopener"><strong>CATALOGUE</strong></a></h3>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-f-radial-blade-centrifugal-fans-in-aluminium/">Dynair F aluminium centrifugal fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Construction:</strong></p>
<ul>
<li>Die cast aluminium volute casing, protected by epoxy paint, with support feet built into the casing.</li>
<li>Single inlet, open blade, die cast aluminium impeller, coupled directly to the motor.</li>
<li>Fixed discharge orientation; RD 270°.</li>
<li>Single-, or three-phase asynchronous motors, with IP55 grade protection and class F insulation, CE marked, compliant with the following international standards: IEC 60034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE.  Suitable for continuous „S1” service at constant load.</li>
</ul>
<p><strong>Accessories:</strong></p>
<ul>
<li>Inlet and outlet protection guards, manufactured according to UNI 12499 standards, protected against atmospheric agents.</li>
</ul>
<p><span style="font-size: 14pt;"><a href="https://www.dynair.hu/contact/" target="_blank" rel="noopener">For further details, feel free to contact KOMPEL Kft.</a></span></p>
<p>The post <a rel="nofollow" href="https://www.dynair.hu/termek/dynair-f-radial-blade-centrifugal-fans-in-aluminium/">Dynair F aluminium centrifugal fans</a> appeared first on <a rel="nofollow" href="https://www.dynair.hu">Dynair.hu</a>.</p>